Numerical Assessments on Laminar Airflow, Thermal Characteristic, and Performance Improvement in a Round Tube Equipped With Combined Vortex Generators

A round tube heat exchanger (RTHE) with combined vortex generators (CVGs) is subjected to numerical assessments of its airflows and thermal characteristics. The CVGs are V‐shaped ribs and rectangular winglets. The effects of CVG arrangement (A‐1, A‐2, and B), blockage ratio ( b 1 / H and b 2 / D ), and airflow direction (+ x , − x ) on airflow and thermal behavior are considered. To solve the numerical problem, a commercial program’s finite volume technique is chosen. Presenting streamlines, fluid temperature distributions, and local Nusselt number contours (on the tube wall) are the numerical findings obtained in the RTHE fitted with the CVG. The study presents the performance analysis of RTHE using dimensionless variables, including the thermal enhancement factor (or thermal performance factor), averaged friction factor, and averaged Nusselt number. The numerical results indicate that the general flow configuration in the RTHE is dramatically altered by the CVG. The mixing quality of the fluid seems to be enhanced. The vortex flows are found through the RTHE. As a result of the vortex flows impinging on the RTHE wall, the thermal boundary layer (T‐BL) over the heat transfer surfaces changes. Enhancing the convective heat transfer coefficient, heat transfer ability, and thermal performance in the RTHE is mostly because of the reduction of the T‐BL thickness. When compared to a smooth round tube, the maximum enhanced heat transfer of the RTHE fitted with the CVG is 13.83 times greater. Furthermore, at Re = 2000, type B, b 1 / D = 0.15, b 2 / D = 0.05, and V‐Upstream scenario, the optimal TEF is 3.81.

Authors

Institutions

Publication Details

Journal
Journal of Engineering
Published
2025-01-01
DOI
https://doi.org/10.1155/je/7036353
Primary Topic
Heat Transfer Mechanisms
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Numerical Assessments on Laminar Airflow, Thermal Characteristic, and Performance Improvement in a Round Tube Equipped With Combined Vortex Generators

Amnart Boonloi, Withada Jedsadaratanachai
Journal of Engineering
Heat Transfer Mechanisms
article

Numerical Assessments on Laminar Airflow, Thermal Characteristic, and Performance Improvement in a Round Tube Equipped With Combined Vortex Generators

Amnart Boonloi, Withada Jedsadaratanachai
article en

Abstract

A round tube heat exchanger (RTHE) with combined vortex generators (CVGs) is subjected to numerical assessments of its airflows and thermal characteristics. The CVGs are V‐shaped ribs and rectangular winglets. The effects of CVG arrangement (A‐1, A‐2, and B), blockage ratio ( b 1 / H and b 2 / D ), and airflow direction (+ x , − x ) on airflow and thermal behavior are considered. To solve the numerical problem, a commercial program’s finite volume technique is chosen. Presenting streamlines, fluid temperature distributions, and local Nusselt number contours (on the tube wall) are the numerical findings obtained in the RTHE fitted with the CVG. The study presents the performance analysis of RTHE using dimensionless variables, including the thermal enhancement factor (or thermal performance factor), averaged friction factor, and averaged Nusselt number. The numerical results indicate that the general flow configuration in the RTHE is dramatically altered by the CVG. The mixing quality of the fluid seems to be enhanced. The vortex flows are found through the RTHE. As a result of the vortex flows impinging on the RTHE wall, the thermal boundary layer (T‐BL) over the heat transfer surfaces changes. Enhancing the convective heat transfer coefficient, heat transfer ability, and thermal performance in the RTHE is mostly because of the reduction of the T‐BL thickness. When compared to a smooth round tube, the maximum enhanced heat transfer of the RTHE fitted with the CVG is 13.83 times greater. Furthermore, at Re = 2000, type B, b 1 / D = 0.15, b 2 / D = 0.05, and V‐Upstream scenario, the optimal TEF is 3.81.

Journal of EngineeringVol. 2025(1)
King Mongkut's University of Technology North Bangkok (TH), King Mongkut's Institute of Technology Ladkrabang (TH)
Openalex Percentile: Top 89%
Heat Transfer Mechanisms
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.