Investigation of the correlation between radiographic image quality and surface measurement quality of XCT using frequency response analysis

X-ray computed tomography (XCT) is developing into a dimensional metrology tool. However, its quality control remains challenging due to the unknown correlation between radiographic image quality and surface measurement quality. This paper investigates this correlation by comparing the modulation transfer function (MTF) of radiographic image with the surface amplitude transfer function (SATF). Results indicate that the limit of measurable surface scale can be predicted by MTF10%. While the shape of the filtering effect on XCT measured surface can be predicted from MTF, the measurement error from this effect cannot be predicted due to the influence of surface determination.

Authors

Publication Details

Journal
CIRP Annals
Published
2025-01-01
DOI
https://doi.org/10.1016/j.cirp.2025.04.031
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Investigation of the correlation between radiographic image quality and surface measurement quality of XCT using frequency response analysis

Paul J. Scott, Xiangqian Jiang, Shan Lou, Wenjuan Sun et al.
CIRP Annals
Advanced X-ray and CT Imaging
article

Investigation of the correlation between radiographic image quality and surface measurement quality of XCT using frequency response analysis

Paul J. Scott, Xiangqian Jiang, Shan Lou, Wenjuan Sun, Xiao Chen
article en

Abstract

X-ray computed tomography (XCT) is developing into a dimensional metrology tool. However, its quality control remains challenging due to the unknown correlation between radiographic image quality and surface measurement quality. This paper investigates this correlation by comparing the modulation transfer function (MTF) of radiographic image with the surface amplitude transfer function (SATF). Results indicate that the limit of measurable surface scale can be predicted by MTF10%. While the shape of the filtering effect on XCT measured surface can be predicted from MTF, the measurement error from this effect cannot be predicted due to the influence of surface determination.

CIRP AnnalsVol. 74(1)
Openalex Percentile: Top 89%
Advanced X-ray and CT Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.