Evaporator and Condenser Fan Speed Control by Varying Cooling Load in Vapor Compression Refrigeration System

Nowadays, a lot of air conditioners use vapor compression refrigeration systems. Behind its function in supporting human needs, refrigeration systems have an impact on increasing electricity consumption. Efforts to save energy in cooling equipment are carried out by increasing its efficiency. One of them is by adding a control system to the fan motor in the evaporator and condenser sections and considering aspects of the cooling load of the refrigeration system itself. This study was conducted to find out more about the performance of the vapor compression refrigeration system with varying evaporator and condenser fan speeds. The fan speed control system uses a VSD (variable speed drive) combined with a servo motor and Arduino Uno R3. Three 5W incandescent light bulbs are placed in the evaporator air inlet, which is used as a cooling load. The final result obtained is that the most optimal control system for the vapor compression refrigeration system is the VSD control system where the electrical energy consumption is lower (which is 0.6 kW) compared to the on-off control system (which is 0.8 kW). Variations in cooling load have a significant effect on air temperature in vapor compression refrigeration systems.

Authors

Institutions

Publication Details

Journal
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Published
2025-05-20
DOI
https://doi.org/10.37934/arfmts.131.2.1725
Citations
1
Primary Topic
Refrigeration and Air Conditioning Technologies
Type
article
Field-Weighted Citation Impact
0.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaporator and Condenser Fan Speed Control by Varying Cooling Load in Vapor Compression Refrigeration System

Zulkifli Amin, Iskandar Ridwan, Leni Permata Sari
1 citations
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences
Refrigeration and Air Conditioning Technologies
0.71
article

Evaporator and Condenser Fan Speed Control by Varying Cooling Load in Vapor Compression Refrigeration System

Zulkifli Amin, Iskandar Ridwan, Leni Permata Sari
article en
1 citations

Abstract

Nowadays, a lot of air conditioners use vapor compression refrigeration systems. Behind its function in supporting human needs, refrigeration systems have an impact on increasing electricity consumption. Efforts to save energy in cooling equipment are carried out by increasing its efficiency. One of them is by adding a control system to the fan motor in the evaporator and condenser sections and considering aspects of the cooling load of the refrigeration system itself. This study was conducted to find out more about the performance of the vapor compression refrigeration system with varying evaporator and condenser fan speeds. The fan speed control system uses a VSD (variable speed drive) combined with a servo motor and Arduino Uno R3. Three 5W incandescent light bulbs are placed in the evaporator air inlet, which is used as a cooling load. The final result obtained is that the most optimal control system for the vapor compression refrigeration system is the VSD control system where the electrical energy consumption is lower (which is 0.6 kW) compared to the on-off control system (which is 0.8 kW). Variations in cooling load have a significant effect on air temperature in vapor compression refrigeration systems.

Journal of Advanced Research in Fluid Mechanics and Thermal SciencesVol. 131(2)
Andalas University (ID)
Universitas Andalas
Openalex Percentile: Top 32%
Refrigeration and Air Conditioning Technologies
0.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Evaporator and Condenser Fan Speed Control by Varying Cooling Load in Vapor Compression Refrigeration System — Zulkifli Amin, Iskandar Ridwan, et al. · Journal of Advanced Research in Fluid Mechanics and Thermal Sciences (2025) | TGRS Research Map | TGRS