Transient Effectiveness Test of Cross Flow Air Heater Heat Exchanger

The problem of high electrical energy consumption in HVAC (heating, ventilation, and air conditioning system), makes renewable energy a solution to the problem. Renewable energy sources such as solar, geothermal, and wind energy are used in reducing electrical energy consumption, which is functioned to warm the room (space heating), drying agricultural products, melting snow-filled roads, heating agricultural land (soil heating), greenhouse heating, and hot springs. heat exchanger is a heat conducting device that can transfer energy from a fluid with a hot temperature to a cold temperature fluid or vice versa which can be used in the application of drying products produced by farmers, plantations, and large or small scale fisheries. Due to the function of the heat exchanger as a room heater, an effectiveness performance test was carried out on the air heater heat exchanger research carried out at the Thermofluid Lab, Department of Mechanical Engineering, Diponegoro University. In this test, several variations of water flow rate and air speed were carried out. There are variations of water flow discharge of 5 liters/minute, 2.5 liters/minute, and 0 liters. In the variation of air velocity there are speeds of 3.6 m/s, 2.7 m/s, and 1.8 m/s. The analysis obtained in the study is that the greatest effectiveness value occurs in the variation of water flow discharge of 2.5 liters/minute with an air speed of 1.8 m/s with a maximum effectiveness value of 0.622 and a minimum of 0.521.

Authors

Publication Details

Journal
International Research Journal of Innovations in Engineering and Technology
Published
2025-01-01
DOI
https://doi.org/10.47001/irjiet/2025.904023
Primary Topic
Engineering Applied Research
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transient Effectiveness Test of Cross Flow Air Heater Heat Exchanger

Muchammad Muchammad, Budi Setiyana, Akmal Hafidh Purnomo
International Research Journal of Innovations in Engineering and Technology
Engineering Applied Research
article

Transient Effectiveness Test of Cross Flow Air Heater Heat Exchanger

Muchammad Muchammad, Budi Setiyana, Akmal Hafidh Purnomo
article en

Abstract

The problem of high electrical energy consumption in HVAC (heating, ventilation, and air conditioning system), makes renewable energy a solution to the problem. Renewable energy sources such as solar, geothermal, and wind energy are used in reducing electrical energy consumption, which is functioned to warm the room (space heating), drying agricultural products, melting snow-filled roads, heating agricultural land (soil heating), greenhouse heating, and hot springs. heat exchanger is a heat conducting device that can transfer energy from a fluid with a hot temperature to a cold temperature fluid or vice versa which can be used in the application of drying products produced by farmers, plantations, and large or small scale fisheries. Due to the function of the heat exchanger as a room heater, an effectiveness performance test was carried out on the air heater heat exchanger research carried out at the Thermofluid Lab, Department of Mechanical Engineering, Diponegoro University. In this test, several variations of water flow rate and air speed were carried out. There are variations of water flow discharge of 5 liters/minute, 2.5 liters/minute, and 0 liters. In the variation of air velocity there are speeds of 3.6 m/s, 2.7 m/s, and 1.8 m/s. The analysis obtained in the study is that the greatest effectiveness value occurs in the variation of water flow discharge of 2.5 liters/minute with an air speed of 1.8 m/s with a maximum effectiveness value of 0.622 and a minimum of 0.521.

International Research Journal of Innovations in Engineering and TechnologyVol. 09(04)
Openalex Percentile: Top 88%
Engineering Applied Research
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Transient Effectiveness Test of Cross Flow Air Heater Heat Exchanger — Muchammad Muchammad, Budi Setiyana, et al. · International Research Journal of Innovations in Engineering and Technology (2025) | TGRS Research Map | TGRS