On-site determination of total phosphorus in natural waters using a novel peroxymonosulfate-based mild digestion method without high temperature or pressure

Total phosphorus is a key indicator of eutrophication, but conventional total phosphorus methods face challenges such as complex operational procedures, bulky instrumentation, and safety risks, limiting on-site rapid analysis. In this study, an on-site total phosphorus determination method was developed by integrating peroxymonosulfate-based advanced oxidation processes with the phosphomolybdenum blue spectrophotometric method. The system was composed of a portable thermal cup for mild sample digestion and a compact spectrophotometer for quantitative analysis, enabling rapid on-site determination of total phosphorus in natural waters without the need for high temperature or pressure. Compared with traditional laboratory methods, operational complexity and equipment footprint were significantly reduced providing a practical solution for real-time water quality monitoring. The effects of initial solution pH, digestion temperature, digestion duration, and peroxymonosulfate concentration on digestion efficiency were systematically investigated, and optimal on-site digestion conditions were determined using response surface methodology. The method exhibited excellent linearity in the range of 0.0-0.6 mg L<sup>-1</sup> and a detection limit of 0.008 mg L<sup>-1</sup>. Spiked recoveries in various matrices were 107.5-116.5%, indicating broad applicability in diverse aquatic environments. The results from actual water samples were consistent with those obtained by the standard method, confirming the reliability and accuracy of the proposed approach for on-site total phosphorus determination.

Authors

Institutions

Publication Details

Journal
Analytical Methods
Published
2025-01-01
DOI
https://doi.org/10.1039/d5ay00728c
Citations
2
Primary Topic
Water Quality Monitoring and Analysis
Type
article
Field-Weighted Citation Impact
1.99

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

On-site determination of total phosphorus in natural waters using a novel peroxymonosulfate-based mild digestion method without high temperature or pressure

Yangyang Cai, Jin Xu, Shuxin Huang, Zuming Zhang et al.
2 citations
Analytical Methods
Water Quality Monitoring and Analysis
1.99
article

On-site determination of total phosphorus in natural waters using a novel peroxymonosulfate-based mild digestion method without high temperature or pressure

Yangyang Cai, Jin Xu, Shuxin Huang, Zuming Zhang, H. T. Li
article en
2 citations

Abstract

Total phosphorus is a key indicator of eutrophication, but conventional total phosphorus methods face challenges such as complex operational procedures, bulky instrumentation, and safety risks, limiting on-site rapid analysis. In this study, an on-site total phosphorus determination method was developed by integrating peroxymonosulfate-based advanced oxidation processes with the phosphomolybdenum blue spectrophotometric method. The system was composed of a portable thermal cup for mild sample digestion and a compact spectrophotometer for quantitative analysis, enabling rapid on-site determination of total phosphorus in natural waters without the need for high temperature or pressure. Compared with traditional laboratory methods, operational complexity and equipment footprint were significantly reduced providing a practical solution for real-time water quality monitoring. The effects of initial solution pH, digestion temperature, digestion duration, and peroxymonosulfate concentration on digestion efficiency were systematically investigated, and optimal on-site digestion conditions were determined using response surface methodology. The method exhibited excellent linearity in the range of 0.0-0.6 mg L<sup>-1</sup> and a detection limit of 0.008 mg L<sup>-1</sup>. Spiked recoveries in various matrices were 107.5-116.5%, indicating broad applicability in diverse aquatic environments. The results from actual water samples were consistent with those obtained by the standard method, confirming the reliability and accuracy of the proposed approach for on-site total phosphorus determination.

Analytical MethodsVol. 17(25)
Guilin University of Electronic Technology (CN)
National Natural Science Foundation of China, National College Students Innovation and Entrepreneurship Training Program, Guangxi Key Research and Development Program, Specific Research Project of Guangxi for Research Bases and Talents
Openalex Percentile: Top 14%
Water Quality Monitoring and Analysis
1.99
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.