Computational Evaluation of a Biomimetic Kinetic Façade Inspired by the Venus Flytrap for Daylight and Glare Performance

Centralized daylight control has been extensively studied for its ability to optimize useful daylight while mitigating glare in targeted areas. However, this approach lacks a comprehensive visual comfort framework, as it does not simultaneously address spatial glare distribution, uniform high useful daylight levels across all sensor points, and overheating prevention through regulated annual solar exposure. Nevertheless, decentralized control facilitates autonomous operation of the individual façade components, addressing all the objectives. This study integrates a biomimetic functional approach with building performance simulations by computational design to evaluate different kinetic façade configurations. Through the implementation of parametric modeling and daylight analysis, we have identified an optimal angular configuration (60° for the focal region, 50° for the non-focal region) that significantly increases building performance. The optimized design demonstrates substantial improvements, reducing excessive sunlight exposure by 45–55% and glare incidence by 65–72% compared to other dynamic solutions. The recommended steeper angles achieve superior performance, maintaining high useful daylight illuminance (UDI > 91.5%) while dramatically improving visual comfort. Sensitivity analysis indicates that even minor angular adjustments (5–10°) can induce a 10–15% variation in glare performance, emphasizing the necessity of precise control mechanisms in both focal and non-focal regions of the façade. These findings establish a framework for creating responsive building façades that balance daylight provision with occupant comfort in real-time operation.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-05-28
DOI
https://doi.org/10.3390/buildings15111853
Citations
3
Primary Topic
Urban Heat Island Mitigation
Type
article
Field-Weighted Citation Impact
2.40

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational Evaluation of a Biomimetic Kinetic Façade Inspired by the Venus Flytrap for Daylight and Glare Performance

Seyed Morteza Hosseini, Farid Farmani, Shahin Hassanzadeh, Morteza Khalaji Assadi
3 citations
Buildings
Urban Heat Island Mitigation
2.40
article

Computational Evaluation of a Biomimetic Kinetic Façade Inspired by the Venus Flytrap for Daylight and Glare Performance

Seyed Morteza Hosseini, Farid Farmani, Shahin Hassanzadeh, Morteza Khalaji Assadi
article en
3 citations

Abstract

Centralized daylight control has been extensively studied for its ability to optimize useful daylight while mitigating glare in targeted areas. However, this approach lacks a comprehensive visual comfort framework, as it does not simultaneously address spatial glare distribution, uniform high useful daylight levels across all sensor points, and overheating prevention through regulated annual solar exposure. Nevertheless, decentralized control facilitates autonomous operation of the individual façade components, addressing all the objectives. This study integrates a biomimetic functional approach with building performance simulations by computational design to evaluate different kinetic façade configurations. Through the implementation of parametric modeling and daylight analysis, we have identified an optimal angular configuration (60° for the focal region, 50° for the non-focal region) that significantly increases building performance. The optimized design demonstrates substantial improvements, reducing excessive sunlight exposure by 45–55% and glare incidence by 65–72% compared to other dynamic solutions. The recommended steeper angles achieve superior performance, maintaining high useful daylight illuminance (UDI > 91.5%) while dramatically improving visual comfort. Sensitivity analysis indicates that even minor angular adjustments (5–10°) can induce a 10–15% variation in glare performance, emphasizing the necessity of precise control mechanisms in both focal and non-focal regions of the façade. These findings establish a framework for creating responsive building façades that balance daylight provision with occupant comfort in real-time operation.

BuildingsVol. 15(11)
University of Tehran (IR), Iran University of Science and Technology (IR), Aalborg University (DK)
Energiteknologisk udviklings- og demonstrationsprogram
Openalex Percentile: Top 12%
Urban Heat Island Mitigation
2.40
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.