Reliability of Ultrasonographic Assessment of Sternal Micromotions by Physiotherapists in Patients with Median Sternotomy

<b>Introduction:</b> Median sternotomy carries post-surgical risks like sternal instability, requiring careful monitoring. Ultrasonography provides a real-time, quantitative assessment of sternal micromovements and has emerged as a promising tool for clinical evaluation. However, its reliability for assessing sternal micromovements post-surgery remains unclear. This study evaluated the inter-rater, intra-rater, and test-retest reliability of ultrasound performed by physiotherapists. <b>Methods:</b> Ultrasound was used to measure the distance between sternal edges in sternotomized patients along the X-axis and Y-axis. Measurements were taken under a resting position, during cough, and in two supine-to-sitting postural transitions (one using a rotational modality and the other with an individual device). Real-time ultrasound imaging acquisition was followed by off-line data elaboration. Assessments were conducted by multiple physiotherapists after a brief training period. Reliability was determined using intraclass correlation coefficients (ICCs), along with the standard error of measurement (SEM) and minimum detectable change (MDC90). ICC values > 0.75 were classified as excellent. <b>Results:</b> A total of 33 subjects with median sternotomy were included (5 women, age 66 ± 7 years). All reliability measurements (24 total) were rated as excellent in each condition examined, with intra-rater ICCs exceeding 0.90, except for on the X-axis during the postural transition using the individual device for supine-to-sitting. SEM values ranged from 0.23 to 0.64 mm, while MDC90 values ranged from 0.54 to 1.50 mm. <b>Conclusions:</b> Ultrasound demonstrated excellent reliability for assessing sternal micromotions when performed by physiotherapists with brief training. Given its reliability, cost-effectiveness, and ease of use, ultrasound sternal micromotions assessment could be integrated into post-surgical rehabilitation to enhance patient care.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-28
DOI
https://doi.org/10.3390/jcm14113770
Primary Topic
Trauma Management and Diagnosis
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reliability of Ultrasonographic Assessment of Sternal Micromotions by Physiotherapists in Patients with Median Sternotomy

Guiti Milani, Marco Godi, Massimo Pistono, Ilaria Arcolin et al.
Journal of Clinical Medicine
Trauma Management and Diagnosis
article

Reliability of Ultrasonographic Assessment of Sternal Micromotions by Physiotherapists in Patients with Median Sternotomy

Guiti Milani, Marco Godi, Massimo Pistono, Ilaria Arcolin, Marica Giardini, Stefano Corna, Marco Guenzi, G. Libiani
article en

Abstract

<b>Introduction:</b> Median sternotomy carries post-surgical risks like sternal instability, requiring careful monitoring. Ultrasonography provides a real-time, quantitative assessment of sternal micromovements and has emerged as a promising tool for clinical evaluation. However, its reliability for assessing sternal micromovements post-surgery remains unclear. This study evaluated the inter-rater, intra-rater, and test-retest reliability of ultrasound performed by physiotherapists. <b>Methods:</b> Ultrasound was used to measure the distance between sternal edges in sternotomized patients along the X-axis and Y-axis. Measurements were taken under a resting position, during cough, and in two supine-to-sitting postural transitions (one using a rotational modality and the other with an individual device). Real-time ultrasound imaging acquisition was followed by off-line data elaboration. Assessments were conducted by multiple physiotherapists after a brief training period. Reliability was determined using intraclass correlation coefficients (ICCs), along with the standard error of measurement (SEM) and minimum detectable change (MDC90). ICC values > 0.75 were classified as excellent. <b>Results:</b> A total of 33 subjects with median sternotomy were included (5 women, age 66 ± 7 years). All reliability measurements (24 total) were rated as excellent in each condition examined, with intra-rater ICCs exceeding 0.90, except for on the X-axis during the postural transition using the individual device for supine-to-sitting. SEM values ranged from 0.23 to 0.64 mm, while MDC90 values ranged from 0.54 to 1.50 mm. <b>Conclusions:</b> Ultrasound demonstrated excellent reliability for assessing sternal micromotions when performed by physiotherapists with brief training. Given its reliability, cost-effectiveness, and ease of use, ultrasound sternal micromotions assessment could be integrated into post-surgical rehabilitation to enhance patient care.

Journal of Clinical MedicineVol. 14(11)
Istituti Clinici Scientifici Maugeri (IT)
Ministero della Salute
Openalex Percentile: Top 79%
Trauma Management and Diagnosis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.