Comparison of Volar Locking Plate versus External Fixation with Additional K Wires for Displaced Distal Radius Fractures
Background: The most frequent fractures of the upper extremities are distal radial fractures, which account for about one-sixth of all fractures treated in emergency rooms. Objective: Comparing the functional, clinical, and radiological results of two distinct fixation methods in patients with displaced distal radial fractures. Patients and methods: Over the course of six months, thirty patients with displaced distal radius fractures were treated; fifteen underwent open reduction and internal fixation using a volar-locked plate (group A), and the remaining fifteen underwent external fixator with K-wires augmentation (group B). The Quick DASH Scoring method, radial volar tilt, radial length, and radial inclination are among the radiological parameters were evaluated.
Authors
- Mohamed M. Baz (ORCID: https://orcid.org/0000-0002-9742-4314)
- Mohamed Hegazy (ORCID: https://orcid.org/0000-0002-2575-2001)
- Hazem Mahmoud Cashlan
Publication Details
- Journal
- Cuestiones de Fisioterapia
- Published
- 2024-12-25
- DOI
- https://doi.org/10.48047/m79k8w43
- Primary Topic
- Orthopedic Surgery and Rehabilitation
- Type
- article
- Field-Weighted Citation Impact
- 0.00