Novel Handheld Device for Remote Monitoring of Dry Macular Degeneration and Patient Usability Assessment

<b>Background/Objectives:</b> A novel, handheld, standalone device using shape discrimination hyperacuity has been developed to remotely monitor age-related macular degeneration (AMD). <b>Methods:</b> We clinically validated the device in an outpatient dry AMD population to evaluate its usability and comfort. A cross-sectional study was conducted with subjects aged 50 years or older with dry AMD at the University of Michigan Kellogg Eye Center outpatient clinic after approval from the UM IRB (HUM00187177). Subjects used the device and then completed a device survey and System Usability Scale (SUS). <b>Results:</b> Thirty-one subjects completed the study, and one subject withdrew post-study completion (mean age 77 years, STD 8 years). The mean testing time was 126 s (STD 56 s), and the median was 116 s. Most patients reported that the use of the device occurred for an acceptable duration (97%), was easy (97%), and was comfortable (90%). The mean SUS score was 77.7 (STD 11.9). <b>Conclusions:</b> A handheld, standalone device can provide a rapid, easy, and comfortable testing solution for patients with dry AMD. The usability of the device supports further clinical trials to demonstrate the device's ability to reliably detect the progression of AMD.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-05-28
DOI
https://doi.org/10.3390/diagnostics15111353
Citations
1
Primary Topic
Retinal Imaging and Analysis
Type
article
Field-Weighted Citation Impact
1.36

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Novel Handheld Device for Remote Monitoring of Dry Macular Degeneration and Patient Usability Assessment

Yannis M. Paulus, Angela Yim, Lyna Azzouz
1 citations
Diagnostics
Retinal Imaging and Analysis
1.36
article

Novel Handheld Device for Remote Monitoring of Dry Macular Degeneration and Patient Usability Assessment

Yannis M. Paulus, Angela Yim, Lyna Azzouz
article en
1 citations

Abstract

<b>Background/Objectives:</b> A novel, handheld, standalone device using shape discrimination hyperacuity has been developed to remotely monitor age-related macular degeneration (AMD). <b>Methods:</b> We clinically validated the device in an outpatient dry AMD population to evaluate its usability and comfort. A cross-sectional study was conducted with subjects aged 50 years or older with dry AMD at the University of Michigan Kellogg Eye Center outpatient clinic after approval from the UM IRB (HUM00187177). Subjects used the device and then completed a device survey and System Usability Scale (SUS). <b>Results:</b> Thirty-one subjects completed the study, and one subject withdrew post-study completion (mean age 77 years, STD 8 years). The mean testing time was 126 s (STD 56 s), and the median was 116 s. Most patients reported that the use of the device occurred for an acceptable duration (97%), was easy (97%), and was comfortable (90%). The mean SUS score was 77.7 (STD 11.9). <b>Conclusions:</b> A handheld, standalone device can provide a rapid, easy, and comfortable testing solution for patients with dry AMD. The usability of the device supports further clinical trials to demonstrate the device's ability to reliably detect the progression of AMD.

DiagnosticsVol. 15(11)
Johns Hopkins University (US), University of Michigan (US), Stanford University (US)
Research to Prevent Blindness, Fight for Sight, National Eye Institute
Openalex Percentile: Top 20%
Retinal Imaging and Analysis
1.36
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.