Low-keV Virtual Monoenergetic Imaging for Bronchial Artery Visualization on Photon-Counting Detector Computed Tomography

<b>Background/Objectives:</b> This study aims to determine the optimal use of virtual monoenergetic imaging (VMI) for visualizing the bronchial artery on photon-counting detector computed tomography (PCD-CT). <b>Methods:</b> We evaluated the visibility of the bronchial artery on PCD-CT in 34 consecutive patients with esophageal cancer (twenty-eight men, six women; mean age, 70.2 years) prior to surgery. Region-of-interest measurements were taken at the right bronchial artery at the tracheal bifurcation level, mediastinal fat, and the erector spinae muscles on contrast-enhanced early-phase CT. We compared the CT attenuation of the bronchial artery, image noise, and contrast-to-noise ratio (CNR) across VMI at 40, 50, 60, and 70 keV. Additionally, two radiologists performed a subjective image quality assessment by comparing VMI at 40, 50, and 60 keV with 70 keV, rating bronchial artery enhancement, border clarity, peripheral visibility, and image noise. <b>Results:</b> CT attenuation, image noise, and CNR significantly differed across VMI energy levels (<i>p</i> < 0.00001). Lower-keV VMI demonstrated higher CT attenuation and increased noise but also higher CNR (all <i>p</i> < 0.05). Both radiologists rated bronchial artery enhancement, border clarity, and peripheral visibility higher at 40 and 50 keV than at 70 keV, with the highest scores observed at 40 keV (all <i>p</i> < 0.05). Observer 1 noted slightly increased noise at 40 and 50 keV, while observer 2 observed this effect at 40 keV compared with 70 keV. <b>Conclusions:</b> Low-keV (40-50 keV) VMI on PCD-CT enhances bronchial artery visualization.

Authors

Institutions

Publication Details

Journal
Diagnostics
Published
2025-05-28
DOI
https://doi.org/10.3390/diagnostics15111354
Citations
2
Primary Topic
Advanced X-ray and CT Imaging
Type
article
Field-Weighted Citation Impact
1.35
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Low-keV Virtual Monoenergetic Imaging for Bronchial Artery Visualization on Photon-Counting Detector Computed Tomography

Xuyang Sun, Jun Hashimoto, Takakiyo Nomura, Tetsu Niwa et al.
2 citations
Diagnostics
Advanced X-ray and CT Imaging
1.35
article

Low-keV Virtual Monoenergetic Imaging for Bronchial Artery Visualization on Photon-Counting Detector Computed Tomography

Xuyang Sun, Jun Hashimoto, Takakiyo Nomura, Tetsu Niwa, Kazuo Koyanagi, Ryoichi Yoshida
article en
2 citations

Abstract

<b>Background/Objectives:</b> This study aims to determine the optimal use of virtual monoenergetic imaging (VMI) for visualizing the bronchial artery on photon-counting detector computed tomography (PCD-CT). <b>Methods:</b> We evaluated the visibility of the bronchial artery on PCD-CT in 34 consecutive patients with esophageal cancer (twenty-eight men, six women; mean age, 70.2 years) prior to surgery. Region-of-interest measurements were taken at the right bronchial artery at the tracheal bifurcation level, mediastinal fat, and the erector spinae muscles on contrast-enhanced early-phase CT. We compared the CT attenuation of the bronchial artery, image noise, and contrast-to-noise ratio (CNR) across VMI at 40, 50, 60, and 70 keV. Additionally, two radiologists performed a subjective image quality assessment by comparing VMI at 40, 50, and 60 keV with 70 keV, rating bronchial artery enhancement, border clarity, peripheral visibility, and image noise. <b>Results:</b> CT attenuation, image noise, and CNR significantly differed across VMI energy levels (<i>p</i> < 0.00001). Lower-keV VMI demonstrated higher CT attenuation and increased noise but also higher CNR (all <i>p</i> < 0.05). Both radiologists rated bronchial artery enhancement, border clarity, and peripheral visibility higher at 40 and 50 keV than at 70 keV, with the highest scores observed at 40 keV (all <i>p</i> < 0.05). Observer 1 noted slightly increased noise at 40 and 50 keV, while observer 2 observed this effect at 40 keV compared with 70 keV. <b>Conclusions:</b> Low-keV (40-50 keV) VMI on PCD-CT enhances bronchial artery visualization.

DiagnosticsVol. 15(11)
Tokai University (JP), Tokai University Hospital (JP)
Openalex Percentile: Top 20%
Advanced X-ray and CT Imaging
1.35
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.