Cavitation Detection Method for Pumps Based on Motor Current Signature Analysis

ABSTRACT Simple and cost‐effective methods for cavitation detection are required for the stable operation of pump systems. Previous researches on cavitation detection systems have used microphones or vibration sensors; however, they are costly and difficult to install. Recently, motor current signature analysis (MCSA) has been gaining attention with regard to motor fault detection. In this paper, we review the characteristics of motor current signals in a cavitation state and propose an MCSA technique for pump cavitation detection. We observed that the foot around the fundamental harmonic spectrum in the power spectral density (PSD) of current signals increased in a cavitation state. Based on these results, we propose defining an evaluation value that reflects the foot and using it for cavitation detection.

Authors

Institutions

Publication Details

Journal
Electrical Engineering in Japan
Published
2025-05-28
DOI
https://doi.org/10.1002/eej.23508
Primary Topic
Oil and Gas Production Techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Cavitation Detection Method for Pumps Based on Motor Current Signature Analysis

Toshihiko Miyauchi, Ken Hirakida, Tomoyuki Iwawaki, Makoto Kanemaru et al.
Electrical Engineering in Japan
Oil and Gas Production Techniques
article

Cavitation Detection Method for Pumps Based on Motor Current Signature Analysis

Toshihiko Miyauchi, Ken Hirakida, Tomoyuki Iwawaki, Makoto Kanemaru, Yasuhiro Kamino, Ryotaro Shinozuka, Koji Irikiin
article en

Abstract

ABSTRACT Simple and cost‐effective methods for cavitation detection are required for the stable operation of pump systems. Previous researches on cavitation detection systems have used microphones or vibration sensors; however, they are costly and difficult to install. Recently, motor current signature analysis (MCSA) has been gaining attention with regard to motor fault detection. In this paper, we review the characteristics of motor current signals in a cavitation state and propose an MCSA technique for pump cavitation detection. We observed that the foot around the fundamental harmonic spectrum in the power spectral density (PSD) of current signals increased in a cavitation state. Based on these results, we propose defining an evaluation value that reflects the foot and using it for cavitation detection.

Electrical Engineering in JapanVol. 218(2)
Mitsubishi Electric (Germany) (DE), Mitsubishi Electric (Japan) (JP)
Openalex Percentile: Top 85%
Oil and Gas Production Techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.