End Shape in Tension Rod That does not Easily Come off even if Load Force Acts at the End

In this study, an end shape in a tension rod that does not easily come off from walls even if load force acts at the end was proposed.The proposed tension rod comprises four parts, and the four parts are a shaft, a spring in the shaft, and left and right ends at both ends of the shaft.The left and right ends are vertical to the central axis of the shaft, and shape of the left and right ends is symmetric about the central axis.Radius of the left and right ends is large, more load force than maximum load force acts at the proposed tension rod, the proposed tension rod leans, and sustainable maximum load force was large.Therefore, the radius of the end shape in the proposed tension rod is large, and the proposed tension rod that does not easily come off from walls even if the load force acts at the end.

Authors

Publication Details

Journal
産業応用工学会論文誌
Published
2025-01-01
DOI
https://doi.org/10.12792/jjiiae.13.1.1
Primary Topic
Mechanical Failure Analysis and Simulation
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

End Shape in Tension Rod That does not Easily Come off even if Load Force Acts at the End

光広 松本
産業応用工学会論文誌
Mechanical Failure Analysis and Simulation
article

End Shape in Tension Rod That does not Easily Come off even if Load Force Acts at the End

光広 松本
article en

Abstract

In this study, an end shape in a tension rod that does not easily come off from walls even if load force acts at the end was proposed.The proposed tension rod comprises four parts, and the four parts are a shaft, a spring in the shaft, and left and right ends at both ends of the shaft.The left and right ends are vertical to the central axis of the shaft, and shape of the left and right ends is symmetric about the central axis.Radius of the left and right ends is large, more load force than maximum load force acts at the proposed tension rod, the proposed tension rod leans, and sustainable maximum load force was large.Therefore, the radius of the end shape in the proposed tension rod is large, and the proposed tension rod that does not easily come off from walls even if the load force acts at the end.

産業応用工学会論文誌Vol. 13(1)
Openalex Percentile: Top 89%
Mechanical Failure Analysis and Simulation
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.