Computational analysis to assess hemodynamic forces in descending thoracic aortic aneurysms

Descending thoracic aortic aneurysm (DTAA) is a life-threatening disorder, defined as a localized enlargement of the descending portion of the thoracic aorta. In this context, we develop a fluid-structure interaction (FSI) computational framework, with the inclusion of a turbulence model and different material properties for the healthy and the aneurysmatic portions of the vessel, to study the hemodynamics and its relationship with DTAA. We first provide an analysis on nine ideal scenarios, accounting for different aortic arch types and DTAA ubications, to study changes in blood pressure, flow patterns, turbulence, wall shear stress, drag forces and internal wall stresses. Our findings demonstrate that the hemodynamics in DTAA is profoundly disturbed, with the presence of flow re-circulation, formation of vortices and transition to turbulence. In particular, configurations with a steeper aortic arch exhibit a more chaotic hemodynamics. We notice also an increase in pressure values for configurations with less steep aortic arch and in drag forces for configurations with distal DTAA. Second, we replicate our analysis for three patient-specific cases (one for type of arch) obtaining comforting results in terms of accordance with the ideal scenarios. Finally, in a very preliminary way, we try to relate our findings to possible stent-graft migrations after TEVAR procedure to provide predictions on the postoperative state. KEY POINTS: This study employs computational methods to assess hemodynamic forces in descending thoracic aortic aneurysms. We consider ideal cases by varying aortic arch type and aneurysm location. Our results show: chaotic hemodynamics for steep aortic arches; increase in pressure values for less steep aortic arches; high risk of plaque deposition in the aneurysmal sac for proximal aneurysms and near the neck for distal aneurysms. We also analyse three patient-specific cases, confirming the major outcomes found for the ideal cases. We try to suggest how our preoperative findings may correlate to assess the risk of stent-graft migration of a possible TEVAR procedure.

Authors

Institutions

Publication Details

Journal
The Journal of Physiology
Published
2025-05-28
DOI
https://doi.org/10.1113/jp287278
Citations
4
Primary Topic
Aortic Disease and Treatment Approaches
Type
article
Field-Weighted Citation Impact
6.07

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Computational analysis to assess hemodynamic forces in descending thoracic aortic aneurysms

Maurizio Domanin, Francesco Migliavacca, Santi Trimarchi, Christian Vergara et al.
4 citations
The Journal of Physiology
Aortic Disease and Treatment Approaches
6.07
article

Computational analysis to assess hemodynamic forces in descending thoracic aortic aneurysms

Maurizio Domanin, Francesco Migliavacca, Santi Trimarchi, Christian Vergara, Francesca Duca, Daniele Bissacco, Luca Crugnola, Chiara Faitini
article en
4 citations

Abstract

Descending thoracic aortic aneurysm (DTAA) is a life-threatening disorder, defined as a localized enlargement of the descending portion of the thoracic aorta. In this context, we develop a fluid-structure interaction (FSI) computational framework, with the inclusion of a turbulence model and different material properties for the healthy and the aneurysmatic portions of the vessel, to study the hemodynamics and its relationship with DTAA. We first provide an analysis on nine ideal scenarios, accounting for different aortic arch types and DTAA ubications, to study changes in blood pressure, flow patterns, turbulence, wall shear stress, drag forces and internal wall stresses. Our findings demonstrate that the hemodynamics in DTAA is profoundly disturbed, with the presence of flow re-circulation, formation of vortices and transition to turbulence. In particular, configurations with a steeper aortic arch exhibit a more chaotic hemodynamics. We notice also an increase in pressure values for configurations with less steep aortic arch and in drag forces for configurations with distal DTAA. Second, we replicate our analysis for three patient-specific cases (one for type of arch) obtaining comforting results in terms of accordance with the ideal scenarios. Finally, in a very preliminary way, we try to relate our findings to possible stent-graft migrations after TEVAR procedure to provide predictions on the postoperative state. KEY POINTS: This study employs computational methods to assess hemodynamic forces in descending thoracic aortic aneurysms. We consider ideal cases by varying aortic arch type and aneurysm location. Our results show: chaotic hemodynamics for steep aortic arches; increase in pressure values for less steep aortic arches; high risk of plaque deposition in the aneurysmal sac for proximal aneurysms and near the neck for distal aneurysms. We also analyse three patient-specific cases, confirming the major outcomes found for the ideal cases. We try to suggest how our preoperative findings may correlate to assess the risk of stent-graft migration of a possible TEVAR procedure.

The Journal of Physiology
University of Milan (IT), Fondazione IRCCS Ca' Granda Ospedale Maggiore Policlinico (IT), École Nationale Supérieure des Mines de Paris (FR), Politecnico di Milano (IT)
Istituto Nazionale di Alta Matematica "Francesco Severi", European Commission, Ministero della Salute, Ministero dell’Istruzione, dell’Università e della Ricerca, Gruppo Nazionale per il Calcolo Scientifico
Openalex Percentile: Top 4%
Aortic Disease and Treatment Approaches
6.07
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.