Research on ZVS Arc Ignition Circuit and Its Conducted Interference

A zero-voltage switching (ZVS) push–pull self-oscillating arc ignition circuit was proposed, marking the first application of ZVS technology in welding arc ignition systems. The circuit’s working principle was analyzed, and time-domain waveforms of the switching transistors verified the realization of soft switching. A conducted interference test platform was established in order to assess the circuit’s electromagnetic compatibility under no-load and arc ignition transient conditions. In comparison with conventional domestic arc ignition circuits, the proposed ZVS circuit demonstrated substantially diminished quasi-peak interference levels, with a reduction exceeding 9.5 dB in both instances. Additionally, under no-load conditions, the ZVS circuit demonstrated interference levels comparable to those of a commercial Fronius system, while during arc ignition transients, it exhibited an over 5 dB reduction. The findings of this study demonstrate that the incorporation of soft-switching techniques into arc ignition circuits can effectively mitigate conducted interference, thus providing a promising and practical approach for industrial welding equipment.

Authors

Institutions

Publication Details

Journal
Electronics
Published
2025-05-28
DOI
https://doi.org/10.3390/electronics14112195
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Research on ZVS Arc Ignition Circuit and Its Conducted Interference

Xiaoqing Lv, Yinghao Li
Electronics
Electrical Fault Detection and Protection
article

Research on ZVS Arc Ignition Circuit and Its Conducted Interference

Xiaoqing Lv, Yinghao Li
article en

Abstract

A zero-voltage switching (ZVS) push–pull self-oscillating arc ignition circuit was proposed, marking the first application of ZVS technology in welding arc ignition systems. The circuit’s working principle was analyzed, and time-domain waveforms of the switching transistors verified the realization of soft switching. A conducted interference test platform was established in order to assess the circuit’s electromagnetic compatibility under no-load and arc ignition transient conditions. In comparison with conventional domestic arc ignition circuits, the proposed ZVS circuit demonstrated substantially diminished quasi-peak interference levels, with a reduction exceeding 9.5 dB in both instances. Additionally, under no-load conditions, the ZVS circuit demonstrated interference levels comparable to those of a commercial Fronius system, while during arc ignition transients, it exhibited an over 5 dB reduction. The findings of this study demonstrate that the incorporation of soft-switching techniques into arc ignition circuits can effectively mitigate conducted interference, thus providing a promising and practical approach for industrial welding equipment.

ElectronicsVol. 14(11)
Tianjin University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 90%
Electrical Fault Detection and Protection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.