Simulation and Optimization of the Antenna Designs for Glucose Biosensing FRET Mechanisms in Endoscopic Capsules

An optimized design of photodetectors and antennas for Förster Resonance Energy Transfer (FRET)-based glucose biosensing in endoscopic capsules is presented. The compact antenna design is tailored for the visible optical frequencies (~526 THz) associated with FRET-based glucose monitoring and integrates structural flexibility to conform to the spatial constraints of endoscopic capsules, such as mechanical bending features. The antenna is embedded in a multimode medium artificial tissue simulating a glucose environment with several layers, providing efficient coupling to the FRET emission signal for glucose sensing. Stable S11 parameters and a maximum gain of 9 dBi are realized by statelier mesh settings, bend adaptation, and cautious SAR constraint handlers. Results of the Specific Absorption Rate (SAR) confirm the limited energy absorption within permissible bounds, confirming its application for biomedical purposes. These results affirm the feasibility of non-invasive glucose measurement in interstitial fluid in this configuration that can be operable through an endoscope with improved sensitivity and functionality.

Authors

Institutions

Publication Details

Journal
Micromachines
Published
2025-05-28
DOI
https://doi.org/10.3390/mi16060641
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Simulation and Optimization of the Antenna Designs for Glucose Biosensing FRET Mechanisms in Endoscopic Capsules

Rizwan Naeem, Doğu Çağdaş Atilla
Micromachines
Advanced biosensing and bioanalysis techniques
article

Simulation and Optimization of the Antenna Designs for Glucose Biosensing FRET Mechanisms in Endoscopic Capsules

Rizwan Naeem, Doğu Çağdaş Atilla
article en

Abstract

An optimized design of photodetectors and antennas for Förster Resonance Energy Transfer (FRET)-based glucose biosensing in endoscopic capsules is presented. The compact antenna design is tailored for the visible optical frequencies (~526 THz) associated with FRET-based glucose monitoring and integrates structural flexibility to conform to the spatial constraints of endoscopic capsules, such as mechanical bending features. The antenna is embedded in a multimode medium artificial tissue simulating a glucose environment with several layers, providing efficient coupling to the FRET emission signal for glucose sensing. Stable S11 parameters and a maximum gain of 9 dBi are realized by statelier mesh settings, bend adaptation, and cautious SAR constraint handlers. Results of the Specific Absorption Rate (SAR) confirm the limited energy absorption within permissible bounds, confirming its application for biomedical purposes. These results affirm the feasibility of non-invasive glucose measurement in interstitial fluid in this configuration that can be operable through an endoscope with improved sensitivity and functionality.

MicromachinesVol. 16(6)
Altınbaş University (TR)
Affordable and clean energy
Openalex Percentile: Top 89%
Advanced biosensing and bioanalysis techniques
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.