Clinical Application of Patient-Specific Bolus Based on Molding and Casting Method in Radiotherapy

<b>Background/Objectives</b>: The use of a patient-specific bolus in radiation therapy is critical for achieving precise dose delivery, particularly for irregular anatomical surfaces. Conventional boluses often suffer from poor conformity and air gaps, leading to suboptimal dose distribution. This study aimed to develop and evaluate a novel bolus fabrication method using the mold-and-casting (M&C) technique, which integrates 3D printing and flexible silicone materials to address these limitations. <b>Methods</b>: The proposed workflow includes CT imaging, 3D modeling, mold fabrication via 3D printing, and silicone casting to produce a patient-specific bolus. The process is followed by quality assurance steps and clinical application. Geometric accuracy was assessed through surface matching and cross-sectional comparisons, and dosimetric performance was evaluated using in vivo measurements with MOSFET detectors. The biocompatibility of the silicone material was tested according to standardized cytotoxicity, skin sensitization, and irritation protocols. <b>Results</b>: The fabricated boluses demonstrated high geometric fidelity, with volumetric and surface discrepancies of less than 3% compared to the planned structures. Dosimetric evaluations indicated that maximum dose differences remained within the clinically acceptable range of ±5%, confirming accurate dose delivery. Biocompatibility tests confirmed that the silicone material is safe for clinical use. <b>Conclusions</b>: The M&C method offers a streamlined approach to patient-specific bolus fabrication that integrates well into existing clinical workflows. Compared to traditional sheet boluses, it significantly reduces air gaps and enhances surface dose uniformity. These findings support the clinical potential of this technique to improve both precision and efficiency in radiation therapy.

Authors

Institutions

Publication Details

Journal
Journal of Clinical Medicine
Published
2025-05-28
DOI
https://doi.org/10.3390/jcm14113796
Citations
1
Primary Topic
Advanced Radiotherapy Techniques
Type
article
Field-Weighted Citation Impact
1.88

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Clinical Application of Patient-Specific Bolus Based on Molding and Casting Method in Radiotherapy

Jiafang Jin, Inbum Lee, Jaeman Son, Jung‐in Kim et al.
1 citations
Journal of Clinical Medicine
Advanced Radiotherapy Techniques
1.88
article

Clinical Application of Patient-Specific Bolus Based on Molding and Casting Method in Radiotherapy

Jiafang Jin, Inbum Lee, Jaeman Son, Jung‐in Kim, Seonghee Kang, Hyojun Park, Yoonsuk Huh, Chang Heon Choi, Hong-Gyun Wu
article en
1 citations

Abstract

<b>Background/Objectives</b>: The use of a patient-specific bolus in radiation therapy is critical for achieving precise dose delivery, particularly for irregular anatomical surfaces. Conventional boluses often suffer from poor conformity and air gaps, leading to suboptimal dose distribution. This study aimed to develop and evaluate a novel bolus fabrication method using the mold-and-casting (M&C) technique, which integrates 3D printing and flexible silicone materials to address these limitations. <b>Methods</b>: The proposed workflow includes CT imaging, 3D modeling, mold fabrication via 3D printing, and silicone casting to produce a patient-specific bolus. The process is followed by quality assurance steps and clinical application. Geometric accuracy was assessed through surface matching and cross-sectional comparisons, and dosimetric performance was evaluated using in vivo measurements with MOSFET detectors. The biocompatibility of the silicone material was tested according to standardized cytotoxicity, skin sensitization, and irritation protocols. <b>Results</b>: The fabricated boluses demonstrated high geometric fidelity, with volumetric and surface discrepancies of less than 3% compared to the planned structures. Dosimetric evaluations indicated that maximum dose differences remained within the clinically acceptable range of ±5%, confirming accurate dose delivery. Biocompatibility tests confirmed that the silicone material is safe for clinical use. <b>Conclusions</b>: The M&C method offers a streamlined approach to patient-specific bolus fabrication that integrates well into existing clinical workflows. Compared to traditional sheet boluses, it significantly reduces air gaps and enhances surface dose uniformity. These findings support the clinical potential of this technique to improve both precision and efficiency in radiation therapy.

Journal of Clinical MedicineVol. 14(11)
Seoul National University (KR), Seoul National University Hospital (KR), Chung-Ang University Hospital (KR)
Seoul National University, Seoul National University Hospital, Ministry of SMEs and Startups
Openalex Percentile: Top 16%
Advanced Radiotherapy Techniques
1.88
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.