Reconfiguration/Immobilization “Dual-Free” Self-Powered Multiplex Photoelectrochemical Strategy for Dual Magnetic Bead-Mediated Dimension Differentiate Type Complex Sample Assay

Despite significant advances in single-interface multiplex photoelectrochemical (PEC) sensors, their potential in high-throughput complex sample analysis is still limited by time-consuming immobilization and cumbersome surface reconfiguration procedures. Particularly for the rapidly growing demand for point-of-care testing, there is an urgent need to explore fast, low-consumption, and sustainable multisignal differentiation approaches ready for implantation into a portable sensor. Herein, a dual magnetic bead-mediated reconfiguration/immobilization "dual-free" strategy is proposed for self-powered PEC sensing of multiple targets on a single electrode. The dual magnetic bead-mediated dimension-differentiated system is formed by two size-differentiated magnetic beads (MBs) and methylene blue-loaded liposomes (MLLs). A large MB is involved in obtaining the MLL signal label via magnetic separation, which modulates the electron transfer mechanism and generates a detection signal. After physically controlled release, the small MB (second signal label) magnetically anchors at the electrode interface to produce another detection signal. By circumventing chemical immobilization and interface reconfiguration, the "dual-free" strategy realizes the rapid, low-cost, sequential, and nondestructive detection of coexisting antibiotics (kanamycin and tobramycin). To further reduce the dimensions and power consumption of the sensing device, a self-powered dual-photoelectrode system is established and instrumented. The reconfiguration/immobilization "dual-free" self-powered sensor eliminates cross-interference, preserves electrode integrity, and avoids external power requirements, thereby pioneering a universal approach for developing miniaturized PEC sensors with great promise for point-of-care testing.

Authors

Institutions

Publication Details

Journal
Analytical Chemistry
Published
2025-05-28
DOI
https://doi.org/10.1021/acs.analchem.5c01314
Citations
3
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
2.42

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Reconfiguration/Immobilization “Dual-Free” Self-Powered Multiplex Photoelectrochemical Strategy for Dual Magnetic Bead-Mediated Dimension Differentiate Type Complex Sample Assay

Wenbo Song, Jingyao Peng, Daqian Song, Yanru Zhang et al.
3 citations
Analytical Chemistry
Advanced biosensing and bioanalysis techniques
2.42
article

Reconfiguration/Immobilization “Dual-Free” Self-Powered Multiplex Photoelectrochemical Strategy for Dual Magnetic Bead-Mediated Dimension Differentiate Type Complex Sample Assay

Wenbo Song, Jingyao Peng, Daqian Song, Yanru Zhang, Xue Fan, Xuechen Zhang, Shan Jiang
article en
3 citations

Abstract

Despite significant advances in single-interface multiplex photoelectrochemical (PEC) sensors, their potential in high-throughput complex sample analysis is still limited by time-consuming immobilization and cumbersome surface reconfiguration procedures. Particularly for the rapidly growing demand for point-of-care testing, there is an urgent need to explore fast, low-consumption, and sustainable multisignal differentiation approaches ready for implantation into a portable sensor. Herein, a dual magnetic bead-mediated reconfiguration/immobilization "dual-free" strategy is proposed for self-powered PEC sensing of multiple targets on a single electrode. The dual magnetic bead-mediated dimension-differentiated system is formed by two size-differentiated magnetic beads (MBs) and methylene blue-loaded liposomes (MLLs). A large MB is involved in obtaining the MLL signal label via magnetic separation, which modulates the electron transfer mechanism and generates a detection signal. After physically controlled release, the small MB (second signal label) magnetically anchors at the electrode interface to produce another detection signal. By circumventing chemical immobilization and interface reconfiguration, the "dual-free" strategy realizes the rapid, low-cost, sequential, and nondestructive detection of coexisting antibiotics (kanamycin and tobramycin). To further reduce the dimensions and power consumption of the sensing device, a self-powered dual-photoelectrode system is established and instrumented. The reconfiguration/immobilization "dual-free" self-powered sensor eliminates cross-interference, preserves electrode integrity, and avoids external power requirements, thereby pioneering a universal approach for developing miniaturized PEC sensors with great promise for point-of-care testing.

Analytical ChemistryVol. 97(22)
Liaoning Normal University (CN), Jilin University (CN), Jilin Medical University (CN)
National Natural Science Foundation of China
Openalex Percentile: Top 11%
Advanced biosensing and bioanalysis techniques
2.42
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.