Effect of a 4 mm vs. a 6 mm Diameter Mold on the Depth of Cure of 6 Bulk-Fill Resin-Based Composites

Dental researchers and manufacturers use the ISO 4049 standard to determine the depth of cure (DoC) of resin-based composites (RBCs). This standard uses a 4 mm diameter stainless-steel mold and subsequently divides the length of the remaining hard RBC by 2. However, the DoC values obtained using this mold have been challenged. Six bulk-fill RBCs (Tetric plus Fill, Tetric plus Flow, Tetric PowerFill, Tetric PowerFlow, Filtek One, and Aura Bulk Fill) were used to investigate the limitations of the 4 mm diameter mold used in the ISO 4049 standard when compared to a 6 mm diameter metal mold that represented the dimensions of a large cavity in a tooth. Two distinct light curing units were used. One light (Elipar S10) emitted a single peak wavelength of light, while the other (Bluephase G4) was a broad-spectrum, multiple-peak curing light. After 10 s of photocuring, the uncured RBC was immediately removed using acetone. The maximum length of the hard RBC remaining was measured and divided by two so that the effect of these two mold diameters on the DoC results could be compared. The DoC of all six RBCs tested was consistently greater in the 6 mm diameter mold (<i>p</i> < 0.0001). Sectioning revealed that the solvent-dissolved specimens had a clear internal boundary between the apparently well-cured RBC and a peripheral, solvent-resistant, "frosty" region. Using a 4 mm diameter stainless-steel mold resulted in a reduced depth of cure values compared to those obtained when the 6 mm diameter mold was used. The use of a broad-spectrum, multiple-peak LED curing light proved unnecessary for photocuring the six RBCs used in this study.

Authors

Institutions

Publication Details

Journal
Materials
Published
2025-05-28
DOI
https://doi.org/10.3390/ma18112548
Primary Topic
Dental materials and restorations
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of a 4 mm vs. a 6 mm Diameter Mold on the Depth of Cure of 6 Bulk-Fill Resin-Based Composites

Richard Bengt Price, A. Gulati, Alex Gareau
Materials
Dental materials and restorations
article

Effect of a 4 mm vs. a 6 mm Diameter Mold on the Depth of Cure of 6 Bulk-Fill Resin-Based Composites

Richard Bengt Price, A. Gulati, Alex Gareau
article en

Abstract

Dental researchers and manufacturers use the ISO 4049 standard to determine the depth of cure (DoC) of resin-based composites (RBCs). This standard uses a 4 mm diameter stainless-steel mold and subsequently divides the length of the remaining hard RBC by 2. However, the DoC values obtained using this mold have been challenged. Six bulk-fill RBCs (Tetric plus Fill, Tetric plus Flow, Tetric PowerFill, Tetric PowerFlow, Filtek One, and Aura Bulk Fill) were used to investigate the limitations of the 4 mm diameter mold used in the ISO 4049 standard when compared to a 6 mm diameter metal mold that represented the dimensions of a large cavity in a tooth. Two distinct light curing units were used. One light (Elipar S10) emitted a single peak wavelength of light, while the other (Bluephase G4) was a broad-spectrum, multiple-peak curing light. After 10 s of photocuring, the uncured RBC was immediately removed using acetone. The maximum length of the hard RBC remaining was measured and divided by two so that the effect of these two mold diameters on the DoC results could be compared. The DoC of all six RBCs tested was consistently greater in the 6 mm diameter mold (<i>p</i> < 0.0001). Sectioning revealed that the solvent-dissolved specimens had a clear internal boundary between the apparently well-cured RBC and a peripheral, solvent-resistant, "frosty" region. Using a 4 mm diameter stainless-steel mold resulted in a reduced depth of cure values compared to those obtained when the 6 mm diameter mold was used. The use of a broad-spectrum, multiple-peak LED curing light proved unnecessary for photocuring the six RBCs used in this study.

MaterialsVol. 18(11)
Dalhousie University (CA)
Dalhousie University, Research Nova Scotia
Openalex Percentile: Top 88%
Dental materials and restorations
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.