Determination of the Reliability and Accuracy of the Brix Refractometer for the Detection of Colostrum Quality in Sheep

This study was aimed at the assessment of the reliability and performance of the Brix refractometer for the determination of colostral IgG concentrations in sheep. A total of 190 colostrum samples were collected from 150 ewes of various breeds. Out of the colostrum samples, 101 were taken at parturition, 10 at 6 h postpartum, 6 at 8 h postpartum, 2 at 10 h postpartum, 65 at 12 h postpartum and 6 at 24 h postpartum. The Brix percentages of the colostrum samples were determined using a Brix refractometer, and the colostral IgG concentrations were measured with the radial immunodiffusion (RID) technique. Correlation coefficients were calculated between the Brix percentages and RID-IgG values. Receiver operating characteristics (ROC) analyses were performed to determine the optimal Brix thresholds for the prediction of colostral IgG concentrations using <20, <50, <75 and <100 g/L thresholds. The misclassification cost term (MCT) analyses were performed to test the robustness of the Brix thresholds based on the relative costs of misclassifications. The mean IgG concentration and Brix percentage of the ewe colostrum samples were determined as 62.7 g/L and 27.2%, respectively. A high correlation was detected between the colostral RID-IgG concentrations and Brix percentages (r = 0.83). Brix percentages of ≤25.0%, ≤25.9%, ≤27.5% and ≤31.9% indicated IgG concentrations of <20, <50, <75 and <100 g/L, respectively. The Brix refractometer was demonstrated to be a low-cost, practical and reliable tool for the determination of colostrum quality in sheep. It is recommended that the four Brix thresholds determined in this study be used strategically in feeding lambs in need of colostral supplementation due to inadequate or poor-quality colostrum production by their dams.

Authors

Institutions

Publication Details

Journal
Veterinary Medicine and Science
Published
2025-05-28
DOI
https://doi.org/10.1002/vms3.70433
Citations
2
Primary Topic
Animal health and immunology
Type
article
Field-Weighted Citation Impact
4.71

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determination of the Reliability and Accuracy of the Brix Refractometer for the Detection of Colostrum Quality in Sheep

Sébastien Buczinski, Umut Can Gündoğar, Ceyhan Özbeyaz, Mehmet Akköse et al.
2 citations
Veterinary Medicine and Science
Animal health and immunology
4.71
article

Determination of the Reliability and Accuracy of the Brix Refractometer for the Detection of Colostrum Quality in Sheep

Sébastien Buczinski, Umut Can Gündoğar, Ceyhan Özbeyaz, Mehmet Akköse, Necmettin Ünal
article en
2 citations

Abstract

This study was aimed at the assessment of the reliability and performance of the Brix refractometer for the determination of colostral IgG concentrations in sheep. A total of 190 colostrum samples were collected from 150 ewes of various breeds. Out of the colostrum samples, 101 were taken at parturition, 10 at 6 h postpartum, 6 at 8 h postpartum, 2 at 10 h postpartum, 65 at 12 h postpartum and 6 at 24 h postpartum. The Brix percentages of the colostrum samples were determined using a Brix refractometer, and the colostral IgG concentrations were measured with the radial immunodiffusion (RID) technique. Correlation coefficients were calculated between the Brix percentages and RID-IgG values. Receiver operating characteristics (ROC) analyses were performed to determine the optimal Brix thresholds for the prediction of colostral IgG concentrations using <20, <50, <75 and <100 g/L thresholds. The misclassification cost term (MCT) analyses were performed to test the robustness of the Brix thresholds based on the relative costs of misclassifications. The mean IgG concentration and Brix percentage of the ewe colostrum samples were determined as 62.7 g/L and 27.2%, respectively. A high correlation was detected between the colostral RID-IgG concentrations and Brix percentages (r = 0.83). Brix percentages of ≤25.0%, ≤25.9%, ≤27.5% and ≤31.9% indicated IgG concentrations of <20, <50, <75 and <100 g/L, respectively. The Brix refractometer was demonstrated to be a low-cost, practical and reliable tool for the determination of colostrum quality in sheep. It is recommended that the four Brix thresholds determined in this study be used strategically in feeding lambs in need of colostral supplementation due to inadequate or poor-quality colostrum production by their dams.

Veterinary Medicine and ScienceVol. 11(4)
Ankara University (TR), Université de Montréal (CA)
Ankara Universitesi, Türkiye Bilimsel ve Teknolojik Araştırma Kurumu
No poverty
Openalex Percentile: Top 6%
Animal health and immunology
4.71
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.