Effects of electric field and heat distribution due to trends in metal stent diameter in epicardial pulsed field ablation

The autonomic nervous system of the heart plays a crucial role in the onset and progression of atrial fibrillation (AF). Selective ablation of the epicardial autonomic nervous system has been proposed as a potential treatment for AF. Metallic stents implanted in the epicardial fat layer of coronary arteries may undergo diameter changes due to plaque accumulation and vascular alterations. However, the impact of these changes on the electric field and temperature distribution in the ablation region remains unexplored. Two-dimensional and three-dimensional computational models were developed for the ablation region. To manage model complexity, plaque and vessels were simplified. Additionally, a 1:1 model of the ablation catheter was created to enhance data accuracy. The pulsed electric field ablation area was assessed using a field strength contour of 1000 V/cm. When the trend of metal stent diameter changes was consistent, the maximum difference in ablation area width between the two-dimensional and three-dimensional models was 0.3 mm, and the maximum temperature difference was 0.3 °C. When the trend of metal stent diameter changes was inconsistent, the maximum difference in ablation area width reached 1.95 mm, while the maximum temperature difference was 0.6 °C. Variations in metal stent diameter may have a greater impact on ablation area width. Therefore, we simulated different cross-section calculations for various models. A comparison of the two-dimensional and three-dimensional models showed that the maximum difference in ablation area width was 0.1 mm, while the maximum temperature difference was 0.5 °C. In the epicardial ablation model, variations in coronary metal stent diameter significantly impact the width of the ablation area. Considering the influence of metal stent diameter on the ablation area, the three-dimensional model provides more accurate calculations. When variations in metal stent diameter are not considered, the discrepancy between 2D and 3D model calculations is smaller. Furthermore, our study demonstrated that PFA ablation in regions with metal stents may alter the ablation effect, which has important clinical implications for the use of PFA in AF treatment.

Authors

Institutions

Publication Details

Journal
Scientific Reports
Published
2025-05-28
DOI
https://doi.org/10.1038/s41598-025-01965-5
Citations
1
Primary Topic
Cardiac Arrhythmias and Treatments
Type
article
Field-Weighted Citation Impact
1.39
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effects of electric field and heat distribution due to trends in metal stent diameter in epicardial pulsed field ablation

Ming Liang, Yunhao Li, Yaling Han, Jie Zhang et al.
1 citations
Scientific Reports
Cardiac Arrhythmias and Treatments
1.39
article

Effects of electric field and heat distribution due to trends in metal stent diameter in epicardial pulsed field ablation

Ming Liang, Yunhao Li, Yaling Han, Jie Zhang, Jingyang Sun, Zhen Wang, Daoyang Zhang
article en
1 citations

Abstract

The autonomic nervous system of the heart plays a crucial role in the onset and progression of atrial fibrillation (AF). Selective ablation of the epicardial autonomic nervous system has been proposed as a potential treatment for AF. Metallic stents implanted in the epicardial fat layer of coronary arteries may undergo diameter changes due to plaque accumulation and vascular alterations. However, the impact of these changes on the electric field and temperature distribution in the ablation region remains unexplored. Two-dimensional and three-dimensional computational models were developed for the ablation region. To manage model complexity, plaque and vessels were simplified. Additionally, a 1:1 model of the ablation catheter was created to enhance data accuracy. The pulsed electric field ablation area was assessed using a field strength contour of 1000 V/cm. When the trend of metal stent diameter changes was consistent, the maximum difference in ablation area width between the two-dimensional and three-dimensional models was 0.3 mm, and the maximum temperature difference was 0.3 °C. When the trend of metal stent diameter changes was inconsistent, the maximum difference in ablation area width reached 1.95 mm, while the maximum temperature difference was 0.6 °C. Variations in metal stent diameter may have a greater impact on ablation area width. Therefore, we simulated different cross-section calculations for various models. A comparison of the two-dimensional and three-dimensional models showed that the maximum difference in ablation area width was 0.1 mm, while the maximum temperature difference was 0.5 °C. In the epicardial ablation model, variations in coronary metal stent diameter significantly impact the width of the ablation area. Considering the influence of metal stent diameter on the ablation area, the three-dimensional model provides more accurate calculations. When variations in metal stent diameter are not considered, the discrepancy between 2D and 3D model calculations is smaller. Furthermore, our study demonstrated that PFA ablation in regions with metal stents may alter the ablation effect, which has important clinical implications for the use of PFA in AF treatment.

Scientific ReportsVol. 15(1)
Dalian Medical University (CN), General Hospital of Shenyang Military Region (CN), China Medical University (CN), Northeastern University (CN)
Affordable and clean energy
Openalex Percentile: Top 19%
Cardiac Arrhythmias and Treatments
1.39
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.