Synchrophasor-Based Islanding Detection for Distributed Generation Applications

A Rural Electric Cooperative (CO-OP) is a medium sized utility based in Colorado with a 69 kV subtransmission used primarily to feed their industrial members. The CO-OP is adding 180 MW of natural gas combustion turbine generation onto this sub-transmission network. The network is wholly owned by the CO-OP and is fed from multiple sources of which they own. Multiple sources, switching configurations, and ring buses feeding these sources make breaker status impractical for islanding detection. There exist scenarios outside the sub-transmission system that can lead to an islanded system. If the load and generation are closely matched, then local-islanding detection is not viable to detect an island. The CO-OP will use synchrophasor-based islanding detection in conjunction with over and under-frequency to detect an island.

Authors

Publication Details

Published
2025-04-29
DOI
https://doi.org/10.1109/repc60353.2025.00018
Primary Topic
Islanding Detection in Power Systems
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Synchrophasor-Based Islanding Detection for Distributed Generation Applications

Timothy Clements, Victoria Ibarra, Sophie Halter, Andrew Spero et al.
Islanding Detection in Power Systems
article

Synchrophasor-Based Islanding Detection for Distributed Generation Applications

Timothy Clements, Victoria Ibarra, Sophie Halter, Andrew Spero, Colin Hovden, Caileighan Hoyt, Carson Bates
article en

Abstract

A Rural Electric Cooperative (CO-OP) is a medium sized utility based in Colorado with a 69 kV subtransmission used primarily to feed their industrial members. The CO-OP is adding 180 MW of natural gas combustion turbine generation onto this sub-transmission network. The network is wholly owned by the CO-OP and is fed from multiple sources of which they own. Multiple sources, switching configurations, and ring buses feeding these sources make breaker status impractical for islanding detection. There exist scenarios outside the sub-transmission system that can lead to an islanded system. If the load and generation are closely matched, then local-islanding detection is not viable to detect an island. The CO-OP will use synchrophasor-based islanding detection in conjunction with over and under-frequency to detect an island.

Openalex Percentile: Top 90%
Islanding Detection in Power Systems
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.