Practical Considerations for Appropriate Arrester Selection

This paper explores the technical challenges and considerations involved in the selection and sizing of surge arrester protection. A recent review of surge arrester sizing based on dynamic simulation results suggested the need for a higher maximum continuous operating voltage (MCOV) rating than what was preliminarily specified. However, subsequent insulation coordination studies, a detailed engineering assessment, along with historical equipment performance considerations indicated that the originally specified arrester size still provides appropriate system protection. By analyzing key standards such as IEEE C62.82.2-2022, this paper examines the balance between protecting equipment insulation and ensuring arrester reliability. The discussion addresses the considerations between upsizing arresters for improved protection margins and the potential drawbacks of specifying arresters with oversized MCOV ratings. Alternative solutions, including dynamic protection settings and advanced insulation coordination techniques, are also considered. The paper concludes by offering recommendations for selecting appropriate arrester sizes that emphasize the need for a pragmatic approach that combines dynamic simulation results along with practical engineering analysis.

Authors

Publication Details

Published
2025-04-29
DOI
https://doi.org/10.1109/repc60353.2025.00020
Primary Topic
Risk and Safety Analysis
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Practical Considerations for Appropriate Arrester Selection

Carson Bates, Eric Senkowicz, Chaitali Naik, Chad Brotherton
Risk and Safety Analysis
article

Practical Considerations for Appropriate Arrester Selection

Carson Bates, Eric Senkowicz, Chaitali Naik, Chad Brotherton
article en

Abstract

This paper explores the technical challenges and considerations involved in the selection and sizing of surge arrester protection. A recent review of surge arrester sizing based on dynamic simulation results suggested the need for a higher maximum continuous operating voltage (MCOV) rating than what was preliminarily specified. However, subsequent insulation coordination studies, a detailed engineering assessment, along with historical equipment performance considerations indicated that the originally specified arrester size still provides appropriate system protection. By analyzing key standards such as IEEE C62.82.2-2022, this paper examines the balance between protecting equipment insulation and ensuring arrester reliability. The discussion addresses the considerations between upsizing arresters for improved protection margins and the potential drawbacks of specifying arresters with oversized MCOV ratings. Alternative solutions, including dynamic protection settings and advanced insulation coordination techniques, are also considered. The paper concludes by offering recommendations for selecting appropriate arrester sizes that emphasize the need for a pragmatic approach that combines dynamic simulation results along with practical engineering analysis.

Openalex Percentile: Top 88%
Risk and Safety Analysis
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Practical Considerations for Appropriate Arrester Selection — Carson Bates, Eric Senkowicz, et al. · (2025) | TGRS Research Map | TGRS