qByte: An open-source isothermal fluorimeter for democratizing analysis of nucleic acids, proteins and cells

Access to affordable and reliable scientific instrumentation remains a significant barrier to the democratization of healthcare and scientific research. In the field of biotechnology, in particular, the complexity, cost, and infrastructure requirements of many instruments continue to limit their accessibility, especially in resource-limited environments. Despite the recent increase in the development of open-source tools, driven by advances in digital fabrication and electronic prototyping, few of these projects have reached large-scale implementation or validation in real-world settings. Here, we present qByte, an open-source, 8-tube isothermal fluorimeter designed to overcome these barriers by offering a cost-effective ($60) yet production-ready solution. qByte leverages standard digital manufacturing and Printed Circuit Board (PCB) assembly techniques and is designed to be portable, making it ideal for both laboratory and field use. The device has been benchmarked against commercial real-time thermocyclers and spectrophotometers, showing comparable results across four key applications: nucleic acid amplification and detection, including the on-site diagnosis of human parasites in Ghana, analysis of protein activity and stability, genetic construct characterization, and bacterial viability tests. Taken together, our results proved qByte as flexible and reliable equipment for a variety of biological tests and applications, while its affordability and open-source design simplify further development and allow adaptation to the needs of future users.

Authors

Institutions

Publication Details

Journal
PLoS Biology
Published
2025-05-28
DOI
https://doi.org/10.1371/journal.pbio.3003199
Citations
3
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
2.02

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

qByte: An open-source isothermal fluorimeter for democratizing analysis of nucleic acids, proteins and cells

Samuel Asamoah Sakyi, Aníbal Arce, Guy Aidelberg, Hortense Vielfaure et al.
3 citations
PLoS Biology
Biosensors and Analytical Detection
2.02
article

qByte: An open-source isothermal fluorimeter for democratizing analysis of nucleic acids, proteins and cells

Samuel Asamoah Sakyi, Aníbal Arce, Guy Aidelberg, Hortense Vielfaure, Ariel B. Lindner, Fernán Federici, Ana Pascual-Garrigos, Francisco J. Quero, Amir Pandi, Jenny Molloy, Urs Gaudenz, Séverine Cazaux, Yann Huon de Kermadec
article en
3 citations

Abstract

Access to affordable and reliable scientific instrumentation remains a significant barrier to the democratization of healthcare and scientific research. In the field of biotechnology, in particular, the complexity, cost, and infrastructure requirements of many instruments continue to limit their accessibility, especially in resource-limited environments. Despite the recent increase in the development of open-source tools, driven by advances in digital fabrication and electronic prototyping, few of these projects have reached large-scale implementation or validation in real-world settings. Here, we present qByte, an open-source, 8-tube isothermal fluorimeter designed to overcome these barriers by offering a cost-effective ($60) yet production-ready solution. qByte leverages standard digital manufacturing and Printed Circuit Board (PCB) assembly techniques and is designed to be portable, making it ideal for both laboratory and field use. The device has been benchmarked against commercial real-time thermocyclers and spectrophotometers, showing comparable results across four key applications: nucleic acid amplification and detection, including the on-site diagnosis of human parasites in Ghana, analysis of protein activity and stability, genetic construct characterization, and bacterial viability tests. Taken together, our results proved qByte as flexible and reliable equipment for a variety of biological tests and applications, while its affordability and open-source design simplify further development and allow adaptation to the needs of future users.

PLoS BiologyVol. 23(5)
Union Bank of Switzerland (CH), Inserm (FR), Pontificia Universidad Católica de Chile (CL), Université Paris Cité (FR), University of Cambridge (GB), Millennium Science Initiative (CL), Kwame Nkrumah University of Science and Technology (GH), Center for Research and Interdisciplinarity (FR), Millennium Institute for Integrative Biology (CL)
Alfred P. Sloan Foundation, Ministère des Affaires Etrangères, Isaac Newton Trust, Fondation Bettencourt Schueller, Agencia Nacional de Investigación y Desarrollo, Trinity College, University of Cambridge
Industry, innovation and infrastructure
Openalex Percentile: Top 14%
Biosensors and Analytical Detection
2.02
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.