Analysis of Electric Field and Temperature Distributions of Non-Uniformly Contaminated Silicone Composite Insulators Using Deep Learning

This study examines the insulation performance of a silicone composite insulator under various contamination conditions. The non-uniform pollution of a silicone composite insulator, operating in a 34.5 kV, 50 Hz power grid under atmospheric conditions, was analyzed using COMSOL Multiphysics. Considering that the conductivity of the contamination layer on the insulator surface affects leakage currents, surface temperature, and electric field distribution, five critical regions of the insulator surface, significant in terms of contamination, were identified, and distinct conductivity levels were assigned to each. Various combinations of these conductivity levels and voltage values were used to calculate the electric field (kV/cm) in the frequency domain and temperature (°C) in the time domain. Data sets were generated for all possible combinations at 29 critical points along the leakage distance. The aim was to identify critical conditions for the electric field and temperature, thus providing a closer approximation to actual operating conditions. Using the obtained data, a Deep Neural Network (DNN)-based model was developed to predict the insulator’s response under varying contamination, current density, and voltage conditions. The model demonstrated consistent predictions for electric field and temperature values under nonuniform pollution conditions. The predictive performance of the proposed model was validated through comparative analysis with established machine learning techniques, including Support Vector Machine (SVM) and Random Forest (RF). The model demonstrated consistent predictions for electric field and temperature values under nonuniform pollution conditions.

Authors

Institutions

Publication Details

Journal
IEEE Access
Published
2025-01-01
DOI
https://doi.org/10.1109/access.2025.3574493
Citations
1
Primary Topic
Electrical Fault Detection and Protection
Type
article
Field-Weighted Citation Impact
0.73
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Analysis of Electric Field and Temperature Distributions of Non-Uniformly Contaminated Silicone Composite Insulators Using Deep Learning

İrem Görgöz, Mehmet Cebeci
1 citations
IEEE Access
Electrical Fault Detection and Protection
0.73
article

Analysis of Electric Field and Temperature Distributions of Non-Uniformly Contaminated Silicone Composite Insulators Using Deep Learning

İrem Görgöz, Mehmet Cebeci
article en
1 citations

Abstract

This study examines the insulation performance of a silicone composite insulator under various contamination conditions. The non-uniform pollution of a silicone composite insulator, operating in a 34.5 kV, 50 Hz power grid under atmospheric conditions, was analyzed using COMSOL Multiphysics. Considering that the conductivity of the contamination layer on the insulator surface affects leakage currents, surface temperature, and electric field distribution, five critical regions of the insulator surface, significant in terms of contamination, were identified, and distinct conductivity levels were assigned to each. Various combinations of these conductivity levels and voltage values were used to calculate the electric field (kV/cm) in the frequency domain and temperature (°C) in the time domain. Data sets were generated for all possible combinations at 29 critical points along the leakage distance. The aim was to identify critical conditions for the electric field and temperature, thus providing a closer approximation to actual operating conditions. Using the obtained data, a Deep Neural Network (DNN)-based model was developed to predict the insulator’s response under varying contamination, current density, and voltage conditions. The model demonstrated consistent predictions for electric field and temperature values under nonuniform pollution conditions. The predictive performance of the proposed model was validated through comparative analysis with established machine learning techniques, including Support Vector Machine (SVM) and Random Forest (RF). The model demonstrated consistent predictions for electric field and temperature values under nonuniform pollution conditions.

IEEE AccessVol. 13
Fırat University (TR)
Openalex Percentile: Top 28%
Electrical Fault Detection and Protection
0.73
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.