Optimal Set of Type-II dc Link Voltage Controller Coefficients for Practical Single-Phase Power Factor Correction Rectifiers Operating Under Grid Current Quality and Voltage Loop Stability Constraints

Type-II and proportional-integrative (PI) compensators are often employed as DC-link voltage controllers in practical single-phase power factor correction rectifiers (PFCRs). Corresponding controller coefficients are typically designed in frequency domain according to a rule-of-thumb imposing crossover frequency around 10 Hz, yielding unnecessarily high (>45°) phase margin. Recently, analytical guidelines for deriving PI controller coefficients set, allowing the system to comply with grid current total harmonic distortion (THD) and DC link voltage loop phase margin (PM) constraints, were established. This paper demonstrates that an additional degree-of-freedom (DOF) present in type-II compensator (compared to PI) permits optimizing DC-link voltage response to load step in addition to the above-mentioned constraints fulfilment. Design guidelines for deriving optimal type-II compensator coefficients set by means of combined time and frequency domain analysis are provided. The revealed findings are accurately supported by simulations and experiments.

Authors

Institutions

Publication Details

Journal
IEEE Journal of Emerging and Selected Topics in Power Electronics
Published
2025-05-28
DOI
https://doi.org/10.1109/jestpe.2025.3574314
Citations
4
Primary Topic
Multilevel Inverters and Converters
Type
article
Field-Weighted Citation Impact
2.92
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimal Set of Type-II dc Link Voltage Controller Coefficients for Practical Single-Phase Power Factor Correction Rectifiers Operating Under Grid Current Quality and Voltage Loop Stability Constraints

Pavel Strajnikov, Alon Kuperman
4 citations
IEEE Journal of Emerging and Selected Topics in Power Electronics
Multilevel Inverters and Converters
2.92
article

Optimal Set of Type-II dc Link Voltage Controller Coefficients for Practical Single-Phase Power Factor Correction Rectifiers Operating Under Grid Current Quality and Voltage Loop Stability Constraints

Pavel Strajnikov, Alon Kuperman
article en
4 citations

Abstract

Type-II and proportional-integrative (PI) compensators are often employed as DC-link voltage controllers in practical single-phase power factor correction rectifiers (PFCRs). Corresponding controller coefficients are typically designed in frequency domain according to a rule-of-thumb imposing crossover frequency around 10 Hz, yielding unnecessarily high (>45°) phase margin. Recently, analytical guidelines for deriving PI controller coefficients set, allowing the system to comply with grid current total harmonic distortion (THD) and DC link voltage loop phase margin (PM) constraints, were established. This paper demonstrates that an additional degree-of-freedom (DOF) present in type-II compensator (compared to PI) permits optimizing DC-link voltage response to load step in addition to the above-mentioned constraints fulfilment. Design guidelines for deriving optimal type-II compensator coefficients set by means of combined time and frequency domain analysis are provided. The revealed findings are accurately supported by simulations and experiments.

IEEE Journal of Emerging and Selected Topics in Power ElectronicsVol. 13(6)
Ben-Gurion University of the Negev (IL)
Affordable and clean energy
Openalex Percentile: Top 9%
Multilevel Inverters and Converters
2.92
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.