Towards Unified CT Reconstruction: Federated Metadata Learning With Personalized Condition-Modulated iRadonMAP
Recent advances in deep learning-based methods have shown great potential in improving low-dose CT image quality. Meanwhile, these methods are constructed based on a large, centralized, and diverse CT dataset from multiple institutions that is difficult to collect and share due to the high-cost acquisition and data privacy regulations. Previously developed federated learning (FL)-based methods enable collaborative and decentralized training without exchanging local data to preserve data privacy. In this work, we focus on analyzing the robustness of FL-based methods against dataset shifts (i.e., the datasets among multiple institutions are from different scanners, different protocols, or different sampling conditions). The results show that the FL-based CT reconstruction methods are sensitive to domain shifts, which can be attributed to the data heterogeneity among multiple institutions. Based on these findings, we propose a unified CT reconstruction method that leverages high-quality metadata (e.g., low-dose images and their corresponding normal-dose counterparts) stored on the cloud server to address the challenge of multi-institutional domain shifts. For simplicity, we refer to the proposed method as FM-iRadonMAP, representing federated metadata learning with a personalized condition-modulated iRadonMAP. Specifically, the FM-iRadonMAP consists of two modules, i.e., Condition Modulated iRadonMap (CM-iRadonMAP) and Federated Metadata Learning (FMDL). CM-iRadonMAP introduces the knowledge of client-specific sampling conditions, i.e., imaging geometries and scan protocols, into iRadonMAP reconstruction network at each client to modulate the reconstruction effectively. FMDL trains a supervised meta model using high-quality metadata in an additional round and then adaptively unifies the network parameters of the meta model with those of the local models from all clients for broadcasting, addressing the issue of data heterogeneity. A large-scale multi-institutional CT dataset is used to validate and evaluate the reconstruction performance of the FM-iRadonMAP. The experimental results demonstrate the feasibility of the FM-iRadonMAP for multi-institutional CT reconstruction with severe data heterogeneity.
Authors
- Jianhua Ma (ORCID: https://orcid.org/0000-0003-2958-1710)
- Ji He (ORCID: https://orcid.org/0000-0001-9811-6500)
- Shiping Chen (ORCID: https://orcid.org/0000-0002-4603-0024)
- Dong Zeng (ORCID: https://orcid.org/0000-0001-6015-5010)
- Hao Wang (ORCID: https://orcid.org/0009-0004-1597-8164)
- Mingqiang Meng (ORCID: https://orcid.org/0000-0003-2076-5441)
- Mingqiang Li (ORCID: https://orcid.org/0000-0001-6308-5062)
Institutions
- Sun Yat-sen University (CN)
- Fifth Affiliated Hospital of Sun Yat-sen University (CN)
- Southern Medical University (CN)
- Xi'an Jiaotong University (CN)
- Guangzhou Medical University (CN)
Publication Details
- Journal
- IEEE Transactions on Radiation and Plasma Medical Sciences
- Published
- 2025-05-28
- DOI
- https://doi.org/10.1109/trpms.2025.3574209
- Primary Topic
- Radiomics and Machine Learning in Medical Imaging
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China
- National Key Research and Development Program of China