Exposure to fungi, bacteria, and endotoxin in a museum, with staff reporting work-related symptoms

Occupational exposure to airborne fungi in indoor environments may pose respiratory health risks. This study aimed to characterize exposure to fungi, bacteria, and endotoxin in a historical museum where the staff reported airway symptoms. Air samples were collected during three separate workdays using personal and stationary samplers. Fungi and bacteria were quantified and identified using MALDI-TOF MS, and the total inflammatory potential was measured through Reactive Oxygen Species (ROS) production in a human cell line. The geometric mean of staff exposure was 5.9 × 10<sup>3</sup> CFU/m<sup>3</sup> fungi, 1.8 × 10<sup>3</sup> CFU/m<sup>3</sup> bacteria, and 7.93 EU/m<sup>3</sup> endotoxin. Staff reported symptoms of the airways, with immediate symptoms upon entering two departments, which exhibited elevated fungal concentrations compared to other departments. The most prevalent fungal species were <i>Aspergillus conicus, A. domesticus, A. pseudoglaucus</i>, <i>A. pseudogracilis</i>, and <i>Cladosporium</i> spp. Concentrations of bacteria were highest when staff were present and without dominance by any particular species. Staff exposure and stationary samples induced ROS production in a cell line, which correlated with concentrations of fungi, bacteria, and endotoxin. Fungi were detected on the museum artifacts, and concentrations of fungi and bacteria increased during handling of the artifacts. In conclusion, staff in the two departments where airway symptoms were reported were exposed to 2 × 10<sup>4</sup> to 7 × 10<sup>4</sup> CFU/m<sup>3</sup> of fungi, primarily <i>Aspergillus</i> spp. and <i>Cladosporium</i>. spp. This exposure constituted both xerophilic species and species commonly found in water-damaged buildings, and they seemed to have developed on artifacts. These findings underscore the importance of developing preventive strategies to protect the health of museum staff. Moreover, it highlights the challenge of managing fungi adapted to varying humidity conditions.

Authors

Institutions

Publication Details

Journal
Journal of Occupational and Environmental Hygiene
Published
2025-05-28
DOI
https://doi.org/10.1080/15459624.2025.2499599
Citations
1
Primary Topic
Conservation Techniques and Studies
Type
article
Field-Weighted Citation Impact
6.15

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Exposure to fungi, bacteria, and endotoxin in a museum, with staff reporting work-related symptoms

Hjördís Birna Árnadóttir, Anne Mette Madsen, Margit W. Frederiksen
1 citations
Journal of Occupational and Environmental Hygiene
Conservation Techniques and Studies
6.15
article

Exposure to fungi, bacteria, and endotoxin in a museum, with staff reporting work-related symptoms

Hjördís Birna Árnadóttir, Anne Mette Madsen, Margit W. Frederiksen
article en
1 citations

Abstract

Occupational exposure to airborne fungi in indoor environments may pose respiratory health risks. This study aimed to characterize exposure to fungi, bacteria, and endotoxin in a historical museum where the staff reported airway symptoms. Air samples were collected during three separate workdays using personal and stationary samplers. Fungi and bacteria were quantified and identified using MALDI-TOF MS, and the total inflammatory potential was measured through Reactive Oxygen Species (ROS) production in a human cell line. The geometric mean of staff exposure was 5.9 × 10<sup>3</sup> CFU/m<sup>3</sup> fungi, 1.8 × 10<sup>3</sup> CFU/m<sup>3</sup> bacteria, and 7.93 EU/m<sup>3</sup> endotoxin. Staff reported symptoms of the airways, with immediate symptoms upon entering two departments, which exhibited elevated fungal concentrations compared to other departments. The most prevalent fungal species were <i>Aspergillus conicus, A. domesticus, A. pseudoglaucus</i>, <i>A. pseudogracilis</i>, and <i>Cladosporium</i> spp. Concentrations of bacteria were highest when staff were present and without dominance by any particular species. Staff exposure and stationary samples induced ROS production in a cell line, which correlated with concentrations of fungi, bacteria, and endotoxin. Fungi were detected on the museum artifacts, and concentrations of fungi and bacteria increased during handling of the artifacts. In conclusion, staff in the two departments where airway symptoms were reported were exposed to 2 × 10<sup>4</sup> to 7 × 10<sup>4</sup> CFU/m<sup>3</sup> of fungi, primarily <i>Aspergillus</i> spp. and <i>Cladosporium</i>. spp. This exposure constituted both xerophilic species and species commonly found in water-damaged buildings, and they seemed to have developed on artifacts. These findings underscore the importance of developing preventive strategies to protect the health of museum staff. Moreover, it highlights the challenge of managing fungi adapted to varying humidity conditions.

Journal of Occupational and Environmental HygieneVol. 22(9)
National Research Centre for the Working Environment (DK)
Aase og Ejnar Danielsens Fond
Openalex Percentile: Top 5%
Conservation Techniques and Studies
6.15
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.