Mindray Anesthesia Machine Repair Type Wato Ex-65 at Columbia Asia Special Surgery Hospital Semarang

Anesthesia machines are very important medical equipment in modern medicine, especially in medical procedures and intensive care. This device is designed to provide and control the administration of anesthetic drugs and medical gases to patients safely and accurately. Damage to the oxygen regulator block of the anesthesia machine shows a discrepancy with the indicator reading. This problem is very critical because it can cause the administration of inappropriate oxygen concentrations to patients during anesthesia procedures. This activity aims to support health services at the Columbia Asia Semarang Hospital which has a damaged anesthesia machine and wants to be repaired, namely the Mindray Type Wato EX-65 anesthesia machine. Damage to the device is known by disassembling the device, by visual observation, checking for hose leaks, and measuring at certain points in the device circuit. Based on the analysis carried out, the damage is in the anesthesia machine regulator block. After repairs and functional tests using VT 305 to check the air flow, it was declared suitable for use.

Authors

Institutions

Publication Details

Journal
Journal of Engineering Electrical and Informatics
Published
2025-05-26
DOI
https://doi.org/10.55606/jeei.v5i2.4165
Primary Topic
Augmented Reality Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Mindray Anesthesia Machine Repair Type Wato Ex-65 at Columbia Asia Special Surgery Hospital Semarang

Agus Setiawan, Pramesti Kusumaningtyas, Bayu Wahyudi
Journal of Engineering Electrical and Informatics
Augmented Reality Applications
article

Mindray Anesthesia Machine Repair Type Wato Ex-65 at Columbia Asia Special Surgery Hospital Semarang

Agus Setiawan, Pramesti Kusumaningtyas, Bayu Wahyudi
article en

Abstract

Anesthesia machines are very important medical equipment in modern medicine, especially in medical procedures and intensive care. This device is designed to provide and control the administration of anesthetic drugs and medical gases to patients safely and accurately. Damage to the oxygen regulator block of the anesthesia machine shows a discrepancy with the indicator reading. This problem is very critical because it can cause the administration of inappropriate oxygen concentrations to patients during anesthesia procedures. This activity aims to support health services at the Columbia Asia Semarang Hospital which has a damaged anesthesia machine and wants to be repaired, namely the Mindray Type Wato EX-65 anesthesia machine. Damage to the device is known by disassembling the device, by visual observation, checking for hose leaks, and measuring at certain points in the device circuit. Based on the analysis carried out, the damage is in the anesthesia machine regulator block. After repairs and functional tests using VT 305 to check the air flow, it was declared suitable for use.

Journal of Engineering Electrical and InformaticsVol. 5(2)
Universitas Muhammadiyah Semarang (ID)
Openalex Percentile: Top 90%
Augmented Reality Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.