Diagnostic Value of Superparamagnetic Iron Oxide Nanoparticles as a Tracer for Sentinel Lymph Node Mapping in Early-Stage Cervical Cancer: The Preliminary Clinical Experience

Sentinel lymph node (SLN) mapping has been investigated as part of surgical staging in women with early-stage cervical cancer (CC); however, pelvic lymphadenectomy (PLND) remains the standard of care. This study aimed to assess feasibility and safety of SLN detection using superparamagnetic iron oxide (SPIO) nanoparticles as a tracer in CC. Thirty CC patients presumed to be stage I were included in this study with SPIO administered intracervically as a tracer for SLN mapping using a magnetometer and followed by PLND. The endpoints of the study included the proportion of successful SLN detection, the average number of SLNs per patient, and the proportion of pathologically positive results per patient and per node. The diagnostic accuracy of SPIO nanoparticles for detection of metastatic SLNs was evaluated by Receiver Operating Characteristic (ROC) curve analysis, with the area under the ROC curve (AUC) used to demonstrate the studied method's sensitivity. Safety endpoints were a summary of all reported adverse events. SLNs were detected in all cases, bilaterally in 27 patients (90%). The median number of SLNs per patient was 3.5. Four cases had metastatic SLNs. The general malignancy rate per patient was 13.3%, and per node, it was 0.8%. The malignancy detection rate of SLNs was 100% per patient and 80% per node. The AUC of 1.0 (<i>p</i> < 0.001) confirmed the diagnostic value of the SPIO technique for the detection of metastatic SLNs, with a sensitivity of 100%. No adverse events related to the SPIO administration were reported. SPIO nanoparticles, as a tracer for SLN mapping in early-stage CC patients, demonstrated satisfactory accuracy parameters and safety; however, these data need to be evaluated by further research.

Authors

Institutions

Publication Details

Journal
Journal of Functional Biomaterials
Published
2025-05-26
DOI
https://doi.org/10.3390/jfb16060196
Citations
1
Primary Topic
Endometrial and Cervical Cancer Treatments
Type
article
Field-Weighted Citation Impact
2.06

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Diagnostic Value of Superparamagnetic Iron Oxide Nanoparticles as a Tracer for Sentinel Lymph Node Mapping in Early-Stage Cervical Cancer: The Preliminary Clinical Experience

Rafał Matkowski, Marcin Kryszpin, Piotr Lepka, Andrzej Czekański et al.
1 citations
Journal of Functional Biomaterials
Endometrial and Cervical Cancer Treatments
2.06
article

Diagnostic Value of Superparamagnetic Iron Oxide Nanoparticles as a Tracer for Sentinel Lymph Node Mapping in Early-Stage Cervical Cancer: The Preliminary Clinical Experience

Rafał Matkowski, Marcin Kryszpin, Piotr Lepka, Andrzej Czekański, Tymoteusz Poprawski, Marcin Jędryka, Krzysztof Grobelak
article en
1 citations

Abstract

Sentinel lymph node (SLN) mapping has been investigated as part of surgical staging in women with early-stage cervical cancer (CC); however, pelvic lymphadenectomy (PLND) remains the standard of care. This study aimed to assess feasibility and safety of SLN detection using superparamagnetic iron oxide (SPIO) nanoparticles as a tracer in CC. Thirty CC patients presumed to be stage I were included in this study with SPIO administered intracervically as a tracer for SLN mapping using a magnetometer and followed by PLND. The endpoints of the study included the proportion of successful SLN detection, the average number of SLNs per patient, and the proportion of pathologically positive results per patient and per node. The diagnostic accuracy of SPIO nanoparticles for detection of metastatic SLNs was evaluated by Receiver Operating Characteristic (ROC) curve analysis, with the area under the ROC curve (AUC) used to demonstrate the studied method's sensitivity. Safety endpoints were a summary of all reported adverse events. SLNs were detected in all cases, bilaterally in 27 patients (90%). The median number of SLNs per patient was 3.5. Four cases had metastatic SLNs. The general malignancy rate per patient was 13.3%, and per node, it was 0.8%. The malignancy detection rate of SLNs was 100% per patient and 80% per node. The AUC of 1.0 (<i>p</i> < 0.001) confirmed the diagnostic value of the SPIO technique for the detection of metastatic SLNs, with a sensitivity of 100%. No adverse events related to the SPIO administration were reported. SPIO nanoparticles, as a tracer for SLN mapping in early-stage CC patients, demonstrated satisfactory accuracy parameters and safety; however, these data need to be evaluated by further research.

Journal of Functional BiomaterialsVol. 16(6)
Wroclaw Medical University (PL), Lublin Oncology Center (PL)
Ministerstwo Zdrowia
Openalex Percentile: Top 15%
Endometrial and Cervical Cancer Treatments
2.06
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.