Anterior segment optical coherence tomography in the assessment of optical density and heterogeneity of the trabecular meshwork and perilimbal sclera in open-angle glaucoma

PURPOSE. To study the optical density and heterogeneity of perilimbal sclera and trabecular meshwork in individuals with and without open-angle glaucoma. METHODS . The study included 49 patients (89 eyes), divided into two groups: the study group (45 eyes with open-angle glaucoma stages I–IV) and the control group (44 eyes without glaucoma). All patients underwent standard ophthalmological examinations recommended for glaucoma, as well as anterior chamber angle scanning in four quadrants using anterior segment optical coherence tomography (OCT). Parameters of optical density and heterogeneity of the perilimbal sclera and trabecular meshwork were analyzed. RESULTS . In the study group, the optical density of the trabecular meshwork was higher in the inferior quadrant than in the control group, with a positive correlation to intraocular pressure (IOP). The study group also exhibited lower heterogeneity of the perilimbal sclera in the temporal quadrant compared to the control group. A trend toward reduced optical density in the inferior quadrant as glaucoma stage progressed was observed. Changes in the perilimbal sclera did not correlate with IOP. The optical density of the trabecular meshwork in the superior quadrant and of the perilimbal sclera in all quadrants negatively correlated with age. Meanwhile, perilimbal scleral heterogeneity in the temporal and inferior quadrants positively correlated with age, while in the temporal, superior, and inferior quadrants, it negatively correlated with axial length. CONCLUSION . The optical density and heterogeneity of the perilimbal sclera and trabecular meshwork differ between normal and glaucomatous eyes. Specific parameters vary with glaucoma stage and correlate with IOP. Changes in the optical density and heterogeneity of these structures, as identified by OCT, are consistent with the histopathological findings, suggesting their potential use in clinical practice as predictors of the development and progression of open-angle glaucoma. Further studies on a larger cohort of patients are needed.

Authors

Institutions

Publication Details

Journal
National Journal glaucoma
Published
2025-05-27
DOI
https://doi.org/10.53432/2078-4104-2025-24-2-29-39
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Anterior segment optical coherence tomography in the assessment of optical density and heterogeneity of the trabecular meshwork and perilimbal sclera in open-angle glaucoma

К. Б. Першин, Н. Ф. Пашинова, А. А. Панов, А. Yu. Tsygankov
National Journal glaucoma
Glaucoma and retinal disorders
article

Anterior segment optical coherence tomography in the assessment of optical density and heterogeneity of the trabecular meshwork and perilimbal sclera in open-angle glaucoma

К. Б. Першин, Н. Ф. Пашинова, А. А. Панов, А. Yu. Tsygankov
article en

Abstract

PURPOSE. To study the optical density and heterogeneity of perilimbal sclera and trabecular meshwork in individuals with and without open-angle glaucoma. METHODS . The study included 49 patients (89 eyes), divided into two groups: the study group (45 eyes with open-angle glaucoma stages I–IV) and the control group (44 eyes without glaucoma). All patients underwent standard ophthalmological examinations recommended for glaucoma, as well as anterior chamber angle scanning in four quadrants using anterior segment optical coherence tomography (OCT). Parameters of optical density and heterogeneity of the perilimbal sclera and trabecular meshwork were analyzed. RESULTS . In the study group, the optical density of the trabecular meshwork was higher in the inferior quadrant than in the control group, with a positive correlation to intraocular pressure (IOP). The study group also exhibited lower heterogeneity of the perilimbal sclera in the temporal quadrant compared to the control group. A trend toward reduced optical density in the inferior quadrant as glaucoma stage progressed was observed. Changes in the perilimbal sclera did not correlate with IOP. The optical density of the trabecular meshwork in the superior quadrant and of the perilimbal sclera in all quadrants negatively correlated with age. Meanwhile, perilimbal scleral heterogeneity in the temporal and inferior quadrants positively correlated with age, while in the temporal, superior, and inferior quadrants, it negatively correlated with axial length. CONCLUSION . The optical density and heterogeneity of the perilimbal sclera and trabecular meshwork differ between normal and glaucomatous eyes. Specific parameters vary with glaucoma stage and correlate with IOP. Changes in the optical density and heterogeneity of these structures, as identified by OCT, are consistent with the histopathological findings, suggesting their potential use in clinical practice as predictors of the development and progression of open-angle glaucoma. Further studies on a larger cohort of patients are needed.

National Journal glaucomaVol. 24(2)
Federal Medical-Biological Agency (RU)
Openalex Percentile: Top 81%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.