Devices for intraocular pressure self-tonometry

This article provides an overview of devices self-measurement of (IOP) measurement devices, with a detailed analysis of transpalpebral tonometry techniques. Glaucoma is a dangerous condition that can lead to blindness. Regular IOP monitoring is essential for disease management and assessment of treatment efficacy. Although IOP measurements are typically performed during ophthalmology visits, frequent in-office monitoring is not feasible for all glaucoma patients. In such cases, self-measurement becomes a vital alternative. This review examines various devices that allow patients to measure their IOP without assistance. The following devices are discussed: Self-Tonometer, Proview Phosphene Tonometer, Ocuton tonometer, Tono-Pen and AccuPen devices, rebound tonometry devices iCare HOME and iCare HOME 2, the Triggerfish wearable IOP sensor (designed as a contact lens), and implantable sensors EyeMate IO and SC, as well as ballistic and dynamic transpalpebral tonometers. The article particularly focuses on Russian transpalpebral tonometry devices as a promising method available to a wide range of patients.

Authors

Institutions

Publication Details

Journal
National Journal glaucoma
Published
2025-05-27
DOI
https://doi.org/10.53432/2078-4104-2025-24-2-73-83
Primary Topic
Glaucoma and retinal disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Devices for intraocular pressure self-tonometry

Siplivyĭ Vi, J.V. Kosova, A E Aslamazova, М. Chtioui
National Journal glaucoma
Glaucoma and retinal disorders
article

Devices for intraocular pressure self-tonometry

Siplivyĭ Vi, J.V. Kosova, A E Aslamazova, М. Chtioui
article en

Abstract

This article provides an overview of devices self-measurement of (IOP) measurement devices, with a detailed analysis of transpalpebral tonometry techniques. Glaucoma is a dangerous condition that can lead to blindness. Regular IOP monitoring is essential for disease management and assessment of treatment efficacy. Although IOP measurements are typically performed during ophthalmology visits, frequent in-office monitoring is not feasible for all glaucoma patients. In such cases, self-measurement becomes a vital alternative. This review examines various devices that allow patients to measure their IOP without assistance. The following devices are discussed: Self-Tonometer, Proview Phosphene Tonometer, Ocuton tonometer, Tono-Pen and AccuPen devices, rebound tonometry devices iCare HOME and iCare HOME 2, the Triggerfish wearable IOP sensor (designed as a contact lens), and implantable sensors EyeMate IO and SC, as well as ballistic and dynamic transpalpebral tonometers. The article particularly focuses on Russian transpalpebral tonometry devices as a promising method available to a wide range of patients.

National Journal glaucomaVol. 24(2)
Sechenov University (RU), Federal State Scientific Institution Research Institute of Eye Diseases (RU)
Openalex Percentile: Top 81%
Glaucoma and retinal disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Devices for intraocular pressure self-tonometry — Siplivyĭ Vi, J.V. Kosova, et al. · National Journal glaucoma (2025) | TGRS Research Map | TGRS