A Point-of-Care Device for Theophylline Quantification in Human Milk Using Laser-Induced Graphene Electrodes

Theophylline is commonly used to treat asthma and chronic obstructive pulmonary disease (COPD). It has a narrow therapeutic range (55-110 <i>μ</i>M in blood). If levels are too low, the drug is less effective. If too high, it can cause serious side effects like nausea, seizures, irregular heartbeat, low blood pressure, fainting, or even heart attack. Theophylline has a high transfer ratio (70%) from blood to breast milk, which can cause infant health risks. Monitoring theophylline levels in breast milk can help estimate the mother's blood levels and improve breastfeeding safety. However, no point-of-care (PoC) devices are available to measure theophylline at home. To address this, we developed an electrochemical PoC sensor that measures theophylline in breast milk without any sample preparation. The sensor uses laser-induced graphene (LIG) electrodes with no surface modification and is covered by an absorptive glass fiber layer. The device demonstrated a sensitivity of 0.03 <i>μ</i>A/<i>μ</i>M and a detection limit of 6.5 <i>μ</i>M both suitable for therapeutic monitoring in milk. The device is selective against natural changes in milk at different stages of lactation and against other drugs that may also appear in breast milk. The device provided accurate measurements in spiked human milk samples collected at the first, sixth, and 12th months postpartum, with recovery values ranging between 99.2% and 111.0%. This tool adds to the advancement in maternal and infant healthcare and allows mothers on theophylline to manage their dose and protect their newborns while breastfeeding safely.

Authors

Institutions

Publication Details

Journal
ACS Applied Nano Materials
Published
2025-05-27
DOI
https://doi.org/10.1021/acsanm.5c01407
Citations
7
Primary Topic
Biosensors and Analytical Detection
Type
article
Field-Weighted Citation Impact
4.72

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Point-of-Care Device for Theophylline Quantification in Human Milk Using Laser-Induced Graphene Electrodes

Alessia Tasso, Abdulrahman Al-Shami, Ali Soleimani, Maral P. S. Mousavi et al.
7 citations
ACS Applied Nano Materials
Biosensors and Analytical Detection
4.72
article

A Point-of-Care Device for Theophylline Quantification in Human Milk Using Laser-Induced Graphene Electrodes

Alessia Tasso, Abdulrahman Al-Shami, Ali Soleimani, Maral P. S. Mousavi, Diego García, Sina Khazaee Nejad, Farbod Amirghasemi, Melissa Banks, Aiman A. Yaseen, Haozheng Ma, Mona A. Mohamed
article en
7 citations

Abstract

Theophylline is commonly used to treat asthma and chronic obstructive pulmonary disease (COPD). It has a narrow therapeutic range (55-110 <i>μ</i>M in blood). If levels are too low, the drug is less effective. If too high, it can cause serious side effects like nausea, seizures, irregular heartbeat, low blood pressure, fainting, or even heart attack. Theophylline has a high transfer ratio (70%) from blood to breast milk, which can cause infant health risks. Monitoring theophylline levels in breast milk can help estimate the mother's blood levels and improve breastfeeding safety. However, no point-of-care (PoC) devices are available to measure theophylline at home. To address this, we developed an electrochemical PoC sensor that measures theophylline in breast milk without any sample preparation. The sensor uses laser-induced graphene (LIG) electrodes with no surface modification and is covered by an absorptive glass fiber layer. The device demonstrated a sensitivity of 0.03 <i>μ</i>A/<i>μ</i>M and a detection limit of 6.5 <i>μ</i>M both suitable for therapeutic monitoring in milk. The device is selective against natural changes in milk at different stages of lactation and against other drugs that may also appear in breast milk. The device provided accurate measurements in spiked human milk samples collected at the first, sixth, and 12th months postpartum, with recovery values ranging between 99.2% and 111.0%. This tool adds to the advancement in maternal and infant healthcare and allows mothers on theophylline to manage their dose and protect their newborns while breastfeeding safely.

ACS Applied Nano MaterialsVol. 8(22)
University of Southern California (US), Binghamton University (US)
University of Southern California, National Institute of General Medical Sciences
Zero hunger
Openalex Percentile: Top 5%
Biosensors and Analytical Detection
4.72
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.