Optical Ammonia Sensors Based on Spray-Coated Polyaniline Complexes with Polysulfonic Acids

The optical ammonia-sensing properties of water-dispersible polyaniline (PANI) complexes chemically synthesized in the presence of polysulfonic acids of different structure and chain flexibility were compared for the first time. Flexible-chain poly(styrene-4-sulfonic acid) and poly-(2-acrylamido-2-methyl-1-propanesulfonic acid), as well as semi-rigid-chain poly-4,4'-(2,2'-disulfonic acid)diphenylene-iso-phthalamide and rigid-chain poly-4,4'-(2,2'-disulfonic acid)diphenylene-tere-phthalamide (t-PASA) were used. The sensor films were prepared by a convenient and scalable method-spray coating of aqueous solutions on glass substrates. The optical response time and amplitude of the sensor films in the range of ammonia concentrations from 5 to 200 ppm were investigated. To overcome the influence of humidity and presence of over-stoichiometric protons of the polyacid on the accuracy of ammonia determination treatments of the films in aqueous solutions of NaCl, CaCl<sub>2</sub> and BaCl<sub>2</sub> were tested. The treatment in 1 M CaCl<sub>2</sub> solution for all of the PANI complexes results in a significant improvement in the response time, amplitude and reproducibility. The films of PANI complexes with the flexible-chain polyacids have the highest response amplitude in the range of ammonia concentrations 5-25 ppm. PANI-t-PASA film demonstrated the best sensory properties at ammonia concentrations more than 50 ppm. FTIR spectroscopy showed that CaCl<sub>2</sub> treatment results in cross-linking of sulfoacid groups from adjacent polyacid chains by Ca<sup>2+</sup> ions. Thus, such a treatment results both in the neutralization of excessive protons and a significant reduction in the films' swelling at high humidity.

Authors

Institutions

Publication Details

Journal
Sensors
Published
2025-05-26
DOI
https://doi.org/10.3390/s25113348
Citations
1
Primary Topic
Conducting polymers and applications
Type
article
Field-Weighted Citation Impact
0.61
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optical Ammonia Sensors Based on Spray-Coated Polyaniline Complexes with Polysulfonic Acids

Maria A. Teplonogova, A. A. Nekrasov, Л. И. Демина, O. L. Gribkova et al.
1 citations
Sensors
Conducting polymers and applications
0.61
article

Optical Ammonia Sensors Based on Spray-Coated Polyaniline Complexes with Polysulfonic Acids

Maria A. Teplonogova, A. A. Nekrasov, Л. И. Демина, O. L. Gribkova, V. A. Kabanova, E.I. Rodina
article en
1 citations

Abstract

The optical ammonia-sensing properties of water-dispersible polyaniline (PANI) complexes chemically synthesized in the presence of polysulfonic acids of different structure and chain flexibility were compared for the first time. Flexible-chain poly(styrene-4-sulfonic acid) and poly-(2-acrylamido-2-methyl-1-propanesulfonic acid), as well as semi-rigid-chain poly-4,4'-(2,2'-disulfonic acid)diphenylene-iso-phthalamide and rigid-chain poly-4,4'-(2,2'-disulfonic acid)diphenylene-tere-phthalamide (t-PASA) were used. The sensor films were prepared by a convenient and scalable method-spray coating of aqueous solutions on glass substrates. The optical response time and amplitude of the sensor films in the range of ammonia concentrations from 5 to 200 ppm were investigated. To overcome the influence of humidity and presence of over-stoichiometric protons of the polyacid on the accuracy of ammonia determination treatments of the films in aqueous solutions of NaCl, CaCl<sub>2</sub> and BaCl<sub>2</sub> were tested. The treatment in 1 M CaCl<sub>2</sub> solution for all of the PANI complexes results in a significant improvement in the response time, amplitude and reproducibility. The films of PANI complexes with the flexible-chain polyacids have the highest response amplitude in the range of ammonia concentrations 5-25 ppm. PANI-t-PASA film demonstrated the best sensory properties at ammonia concentrations more than 50 ppm. FTIR spectroscopy showed that CaCl<sub>2</sub> treatment results in cross-linking of sulfoacid groups from adjacent polyacid chains by Ca<sup>2+</sup> ions. Thus, such a treatment results both in the neutralization of excessive protons and a significant reduction in the films' swelling at high humidity.

SensorsVol. 25(11)
Frumkin Institute of Physical Chemistry and Electrochemistry Russian Academy of Sciences (RU), NS Kurnakova Institute of General and Inorganic Chemistry (RU)
Openalex Percentile: Top 36%
Conducting polymers and applications
0.61
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines