Wind Tunnel Tests and Buffeting Response Analysis of Concrete-Filled Steel Tubular Arch Ribs During Cantilever Construction
During the construction of concrete-filled steel tubular (CFST) arch bridges, hollow steel tube arch ribs are typically erected using the cantilever method with cable hoisting. In this construction stage, the arch ribs exhibit low out-of-plane stiffness and are thus highly susceptible to wind-induced vibrations, which may lead to cable failure or even collapse of the structure. Despite these critical risks, research on the aerodynamic performance of CFST arch ribs with different cross-sectional forms during cantilever construction remains limited. Most existing studies focus on individual bridge cases rather than generalized aerodynamic behavior. To obtain generalized aerodynamic parameters and buffeting response characteristics applicable to cantilevered CFST arch ribs, this study investigates two common cross-sectional configurations: four-tube trussed and horizontal dumbbell trussed sections. Sectional model wind tunnel tests were conducted to determine the aerodynamic force coefficients and aerodynamic admittance functions (AAFs) of these arch ribs. Comparisons with commonly used empirical AAF formulations (e.g., the Sears function) indicate that these simplified models, or assumptions equating aerodynamic forces with quasi-steady values, are inaccurate for the studied cross-sections. Considering the influence of the curved arch axis on buffeting behavior, a buffeting analysis computational program was developed, incorporating the experimentally derived aerodynamic characteristics. The program was validated against classical theoretical results and practical measurements from an actual bridge project. Using this program, a parametric analysis was conducted to evaluate the effects of equivalent AAF formulations, coherence functions, first-order mode shapes, and the number of structural modes on the buffeting response. The results show that the buffeting response of cantilevered hollow steel arch ribs is predominantly governed by the first-order mode, which can be effectively approximated using a bending-type mode shape expression.
Authors
- Dagang Lü (ORCID: https://orcid.org/0000-0002-3115-7102)
- Shilong Zhang (ORCID: https://orcid.org/0009-0002-3055-9588)
- Xinrong Wu (ORCID: https://orcid.org/0009-0000-0984-8663)
- Qing Hu (ORCID: https://orcid.org/0000-0002-6532-9718)
Institutions
- Harbin Institute of Technology (CN)
Publication Details
- Journal
- Buildings
- Published
- 2025-05-27
- DOI
- https://doi.org/10.3390/buildings15111837
- Primary Topic
- Fluid Dynamics and Vibration Analysis
- Type
- article
- Field-Weighted Citation Impact
- 0.00
Funders
- National Natural Science Foundation of China