Transformer Fault Detection Based on IAHA Optimized BP Neural Network

In view of the shortcomings of artificial hummingbird algorithm (AHA) and BP neural network algorithm in the process of fault detection, this paper improves the AHA by introducing the chaotic sequence of tent map, and proposes an improved AHA (IAHA), which makes the initialization of hummingbird population more uniform. To test the effectiveness of the IAHA, using IAHA to optimize the BP neural network model, and is applied to fault detection together with AHA-BP model, SSA-BP model and GWO-BP model. The results show that the fault detection accuracy of the proposed IAHA-BP model is 97.5%, AHA-BP model is 92.5%, SSA-BP model is 90%, GWO-BP model is 92.5%. It shows that the proposed IAHA-BP model has higher accuracy in the field of transformer fault detection.

Authors

Institutions

Publication Details

Journal
Journal of big data and computing.
Published
2025-03-01
DOI
https://doi.org/10.62517/jbdc.202501106
Primary Topic
Advanced Computational Techniques and Applications
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Transformer Fault Detection Based on IAHA Optimized BP Neural Network

Zhaohui Liu
Journal of big data and computing.
Advanced Computational Techniques and Applications
article

Transformer Fault Detection Based on IAHA Optimized BP Neural Network

Zhaohui Liu
article en

Abstract

In view of the shortcomings of artificial hummingbird algorithm (AHA) and BP neural network algorithm in the process of fault detection, this paper improves the AHA by introducing the chaotic sequence of tent map, and proposes an improved AHA (IAHA), which makes the initialization of hummingbird population more uniform. To test the effectiveness of the IAHA, using IAHA to optimize the BP neural network model, and is applied to fault detection together with AHA-BP model, SSA-BP model and GWO-BP model. The results show that the fault detection accuracy of the proposed IAHA-BP model is 97.5%, AHA-BP model is 92.5%, SSA-BP model is 90%, GWO-BP model is 92.5%. It shows that the proposed IAHA-BP model has higher accuracy in the field of transformer fault detection.

Journal of big data and computing.Vol. 3(1)
Inner Mongolia Electric Power (China) (CN)
Openalex Percentile: Top 95%
Advanced Computational Techniques and Applications
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.