Effect of Meso Substituents in Tin (IV) Corrole on Chemosensing: Highly Selective Coloro/Fluorimetric Sensing of F <sup>−</sup> and CN <sup>−</sup> Ions and Their Practical Applicability

Here, we synthesized tin (IV)-based chemosensors (5,10,15-tris(4-cyanophenyl)corrolato)tin (IV)-chloride (Sn1) and (5,10,15-tris(methyl-5-formyl-2-methoxybenzoate)corrolato)tin(IV)-chloride (Sn2) and thoroughly characterized them by various spectroscopic techniques. These receptors, Sn1 and Sn2, exhibit selective colorimetric and fluorogenic responses towards fluoride (F<sup>-</sup>) and cyanide (CN<sup>-</sup>) anions. The addition of these analytes significantly enhances the fluorescence intensity. Sn1 exhibits a limit of detection (LOD) of 1.65 μM for F<sup>-</sup> and 1.7 μM for CN<sup>-</sup> ions, while Sn2 has an LOD of 4.8 μM for F<sup>-</sup> detection using the fluorometric method. The association constant was calculated to be 2.42 × 10<sup>4</sup> and 1.45 × 10<sup>4</sup> for the complexation of Sn1 with F<sup>-</sup> and CN<sup>-</sup> and 1.21 × 10<sup>4</sup> for Sn2 with F<sup>-</sup>. The larger binding constant and lower LOD of Sn1 and Sn2 demonstrated the ability to sense even traces of target analytes. The sensing ability of Sn1 and Sn2 was comprehensively evaluated through optical, electrochemical, and theoretical studies. The Benesi-Hildebrand and Job's plots suggested a 1:1 binding interaction between the Sn1/Sn2 and respective anions. The ESI mass spectra of Sn receptor + anion complexes revealed that the sensing mechanism involved the exchange of an axial Cl atom with the incoming anions. In addition to that, real-time analysis was also carried out for the detection of F<sup>-</sup> ion present in the toothpaste and RGB analysis to depict the applicability of tin (IV) receptors for real-time applications.

Authors

Institutions

Publication Details

Journal
Luminescence
Published
2025-05-01
DOI
https://doi.org/10.1002/bio.70187
Primary Topic
Molecular Sensors and Ion Detection
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Effect of Meso Substituents in Tin (IV) Corrole on Chemosensing: Highly Selective Coloro/Fluorimetric Sensing of F − and CN − Ions and Their Practical Applicability

Mariappan Mariappan, Simy Antony, R. Sasikala, Govindan Deviga
Luminescence
Molecular Sensors and Ion Detection
article

Effect of Meso Substituents in Tin (IV) Corrole on Chemosensing: Highly Selective Coloro/Fluorimetric Sensing of F − and CN − Ions and Their Practical Applicability

Mariappan Mariappan, Simy Antony, R. Sasikala, Govindan Deviga
article en

Abstract

Here, we synthesized tin (IV)-based chemosensors (5,10,15-tris(4-cyanophenyl)corrolato)tin (IV)-chloride (Sn1) and (5,10,15-tris(methyl-5-formyl-2-methoxybenzoate)corrolato)tin(IV)-chloride (Sn2) and thoroughly characterized them by various spectroscopic techniques. These receptors, Sn1 and Sn2, exhibit selective colorimetric and fluorogenic responses towards fluoride (F<sup>-</sup>) and cyanide (CN<sup>-</sup>) anions. The addition of these analytes significantly enhances the fluorescence intensity. Sn1 exhibits a limit of detection (LOD) of 1.65 μM for F<sup>-</sup> and 1.7 μM for CN<sup>-</sup> ions, while Sn2 has an LOD of 4.8 μM for F<sup>-</sup> detection using the fluorometric method. The association constant was calculated to be 2.42 × 10<sup>4</sup> and 1.45 × 10<sup>4</sup> for the complexation of Sn1 with F<sup>-</sup> and CN<sup>-</sup> and 1.21 × 10<sup>4</sup> for Sn2 with F<sup>-</sup>. The larger binding constant and lower LOD of Sn1 and Sn2 demonstrated the ability to sense even traces of target analytes. The sensing ability of Sn1 and Sn2 was comprehensively evaluated through optical, electrochemical, and theoretical studies. The Benesi-Hildebrand and Job's plots suggested a 1:1 binding interaction between the Sn1/Sn2 and respective anions. The ESI mass spectra of Sn receptor + anion complexes revealed that the sensing mechanism involved the exchange of an axial Cl atom with the incoming anions. In addition to that, real-time analysis was also carried out for the detection of F<sup>-</sup> ion present in the toothpaste and RGB analysis to depict the applicability of tin (IV) receptors for real-time applications.

LuminescenceVol. 40(5)
SRM Institute of Science and Technology (IN), SASTRA University (IN)
Science and Engineering Research Board
Openalex Percentile: Top 89%
Molecular Sensors and Ion Detection
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Effect of Meso Substituents in Tin (IV) Corrole on Chemosensing: Highly Selective Coloro/Fluorimetric Sensing of F <sup>−</sup> and CN <sup>−</sup> Ions and Their Practical Applicability — Mariappan Mariappan, Simy Antony, et al. · Luminescence (2025) | TGRS Research Map | TGRS