Evaluating a discretized data acquisition method for couch modeling to streamline the commissioning process of radiological instruments

Abstract Background The commissioning of radiotherapy treatment planning system (RTPS) involves many time-consuming tests to maintain consistency between actual and planned dose. As the number of new technologies and peripheral devices increases year by year, there is a need for time-efficient and accurate commissioning of radiation therapy equipment. Couch modeling is one type of commissioning, and there are no recommended values for CT due to differences in equipment calibration between facilities. This study evaluated the optimal electron density (ED) for the couch using discretized gantry angles. Results All discrete-angle groups showed a high correlation between the surface ED and dose difference between the actual and planned doses (| r |> 0.9). AcurosXB did not demonstrate a significant correlation between dose differences and each energy. For a small number of discretized gantry groups, the optimal couch modeling results revealed several combinations of surface and interior ED with the same score. Upon adding all couch thickness scores, all energy scores, and both algorithm scores, the optimal surface and interior EDs with the highest score across all couch thicknesses were 0.4 and 0.07, respectively. Conclusions The optimal couch surface ED dose difference trend was identified, and the effectiveness indicated using the dose difference score from discrete-angle couch modeling. Using this method, couch modeling can be evaluated in a highly precise and quick manner, which helps in the commissioning of complicated linear accelerator and radiological treatment plans.

Authors

Institutions

Publication Details

Journal
The Egyptian Journal of Radiology and Nuclear Medicine
Published
2025-05-27
DOI
https://doi.org/10.1186/s43055-025-01479-0
Primary Topic
Radiation Dose and Imaging
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Evaluating a discretized data acquisition method for couch modeling to streamline the commissioning process of radiological instruments

Shusaku Tsumoto, Tadashi Tani, Yoshinori Tanabe, Kuniaki Katsui et al.
The Egyptian Journal of Radiology and Nuclear Medicine
Radiation Dose and Imaging
article

Evaluating a discretized data acquisition method for couch modeling to streamline the commissioning process of radiological instruments

Shusaku Tsumoto, Tadashi Tani, Yoshinori Tanabe, Kuniaki Katsui, Makiko Higuchi, Syouta Tomimoto, Yusuke Saeki, Hiroko Nishikawa, Masato Tanaka, Okihiro Motoda, Yuki Miyashima
article en

Abstract

Abstract Background The commissioning of radiotherapy treatment planning system (RTPS) involves many time-consuming tests to maintain consistency between actual and planned dose. As the number of new technologies and peripheral devices increases year by year, there is a need for time-efficient and accurate commissioning of radiation therapy equipment. Couch modeling is one type of commissioning, and there are no recommended values for CT due to differences in equipment calibration between facilities. This study evaluated the optimal electron density (ED) for the couch using discretized gantry angles. Results All discrete-angle groups showed a high correlation between the surface ED and dose difference between the actual and planned doses (| r |> 0.9). AcurosXB did not demonstrate a significant correlation between dose differences and each energy. For a small number of discretized gantry groups, the optimal couch modeling results revealed several combinations of surface and interior ED with the same score. Upon adding all couch thickness scores, all energy scores, and both algorithm scores, the optimal surface and interior EDs with the highest score across all couch thicknesses were 0.4 and 0.07, respectively. Conclusions The optimal couch surface ED dose difference trend was identified, and the effectiveness indicated using the dose difference score from discrete-angle couch modeling. Using this method, couch modeling can be evaluated in a highly precise and quick manner, which helps in the commissioning of complicated linear accelerator and radiological treatment plans.

The Egyptian Journal of Radiology and Nuclear MedicineVol. 56(1)
Okayama University (JP), Kawasaki Medical School (JP), Okayama University Hospital (JP), Okayama Rosai Hospital (JP), Kawasaki Medical School Hospital (JP)
Japan Society for the Promotion of Science
Openalex Percentile: Top 82%
Radiation Dose and Imaging
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.