Optimization Analysis of Kitchen Cooking Environment for Air Conditioning Range Hood Based on Thermal Comfort and PM10 Concentration

For the issues of the high temperatures and pollutant accumulation generated during kitchen cooking, this paper proposes a kitchen comfort analysis method based on the air conditioning range hood. The method comprehensively considers the thermal comfort and pollutant concentration in the kitchen and systematically investigates the influence mechanism of the air conditioning range hood’s structural parameters on kitchen comfort. Firstly, the reliability of the simulation model was verified through a comparative analysis of experimental tests and simulation data. Secondly, the temperature field, relative humidity, PM10 concentration, and Predicted Mean Vote (PMV) distribution in the kitchen were analyzed before and after air conditioning activation, confirming its positive effects and limitations. Finally, the optimal structural parameter configuration of the air conditioning range hood was explored in depth by combining orthogonal experiments with Computational Fluid Dynamics (CFD) simulations. The results show that the range hood’s exhaust airflow rate is the dominant factor affecting the PM10 concentration distribution, while the initial diffusion velocity of oil fumes has the most significant impact on reducing the kitchen’s PMV value. When the range hood’s exhaust airflow rate is 15 m3/min, the initial diffusion speed of oil fumes is 0.6 m/s, the air conditioning supply temperature is 20 °C, and the comprehensive evaluation index of kitchen comfort reaches its optimum. Under these conditions, the volume-averaged PMV value in the kitchen is 0.36, which is a decrease of 34.56%, and the spatially averaged PM10 concentration is 41.04 μg, which is a decrease of 69.49%.

Authors

Institutions

Publication Details

Journal
Buildings
Published
2025-05-27
DOI
https://doi.org/10.3390/buildings15111842
Citations
1
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
1.01

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Optimization Analysis of Kitchen Cooking Environment for Air Conditioning Range Hood Based on Thermal Comfort and PM10 Concentration

Liangguo Cheng, Hai Huang, Shunyu Zhang, F. Y. Wang et al.
1 citations
Buildings
Building Energy and Comfort Optimization
1.01
article

Optimization Analysis of Kitchen Cooking Environment for Air Conditioning Range Hood Based on Thermal Comfort and PM10 Concentration

Liangguo Cheng, Hai Huang, Shunyu Zhang, F. Y. Wang, Zhihang Shen, Feng Ye, Zhenlei Chen, Yongqiang Tan
article en
1 citations

Abstract

For the issues of the high temperatures and pollutant accumulation generated during kitchen cooking, this paper proposes a kitchen comfort analysis method based on the air conditioning range hood. The method comprehensively considers the thermal comfort and pollutant concentration in the kitchen and systematically investigates the influence mechanism of the air conditioning range hood’s structural parameters on kitchen comfort. Firstly, the reliability of the simulation model was verified through a comparative analysis of experimental tests and simulation data. Secondly, the temperature field, relative humidity, PM10 concentration, and Predicted Mean Vote (PMV) distribution in the kitchen were analyzed before and after air conditioning activation, confirming its positive effects and limitations. Finally, the optimal structural parameter configuration of the air conditioning range hood was explored in depth by combining orthogonal experiments with Computational Fluid Dynamics (CFD) simulations. The results show that the range hood’s exhaust airflow rate is the dominant factor affecting the PM10 concentration distribution, while the initial diffusion velocity of oil fumes has the most significant impact on reducing the kitchen’s PMV value. When the range hood’s exhaust airflow rate is 15 m3/min, the initial diffusion speed of oil fumes is 0.6 m/s, the air conditioning supply temperature is 20 °C, and the comprehensive evaluation index of kitchen comfort reaches its optimum. Under these conditions, the volume-averaged PMV value in the kitchen is 0.36, which is a decrease of 34.56%, and the spatially averaged PM10 concentration is 41.04 μg, which is a decrease of 69.49%.

BuildingsVol. 15(11)
Ningbo University (CN), Fotile (China) (CN)
Zhejiang Province Public Welfare Technology Application Research Project
Openalex Percentile: Top 25%
Building Energy and Comfort Optimization
1.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.