Robotic Harvest of the Free Ileocolon Flap for Esophageal Reconstruction: A Case Report

The ileocolon flap is a fully autologous, single-stage option in the reconstruction of challenging laryngoesophageal defects, restoring voice and swallowing in patients. This procedure represents one of the most sophisticated cases in the field of reconstructive microsurgery. However, the traditional approach to harvesting the ileocolon flap requires a midline laparotomy, which is associated with several donor site complications. In the literature, a minimally invasive approach for the harvest of this flap, which is complex, associated with numerous morbidities related to laparotomy, and has many modifications to perfect its outcomes, has not yet been defined. The purpose of this report is to describe the technique of robotic harvest of the free ileocolon flap to avoid the risks associated with laparotomy. A 53-year-old patient who underwent laryngectomy and cervical esophagectomy (15-cm defect) for treatment of laryngeal squamous cell carcinoma has been admitted to our department for restoration of voice and swallowing. The robotic surgery system (Da Vinci Xi, Intuitive Surgical) enables precise dissection of the ileum, colon, and ileocolic artery and vein by providing optimized high-definition visualization of the surgical field and enhanced control through robotic arms, which offer a much greater range of motion than the surgeon's hand or laparoscopic systems. The flap included 15 cm of ascending colon, ileocecal valve, 10 cm ileum (voice tube), and 5 cm of chimeric ileal segment (seromuscular patch flap). The flap insetted in the neck in an isoperistaltic fashion; ascending colon end-to-end to the esophageal stumps and voice tube anastomosed to tracheal stump in end-to-side fashion. The microvascular anastomoses were performed to the facial artery and external jugular vein. During a 4-month follow-up period, no complications were observed. The patient can eat solid food and speak with his own voice postoperatively. We believe that robotic harvesting of the free ileocolon flap is a safe, feasible, and effective technique that significantly reduces the risk of morbidity related to the invasiveness of the traditional flap harvesting technique.

Authors

Institutions

Publication Details

Journal
Microsurgery
Published
2025-05-01
DOI
https://doi.org/10.1002/micr.70076
Primary Topic
Tracheal and airway disorders
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Robotic Harvest of the Free Ileocolon Flap for Esophageal Reconstruction: A Case Report

Gökhan Sert, Nezih Akkapulu
Microsurgery
Tracheal and airway disorders
article

Robotic Harvest of the Free Ileocolon Flap for Esophageal Reconstruction: A Case Report

Gökhan Sert, Nezih Akkapulu
article en

Abstract

The ileocolon flap is a fully autologous, single-stage option in the reconstruction of challenging laryngoesophageal defects, restoring voice and swallowing in patients. This procedure represents one of the most sophisticated cases in the field of reconstructive microsurgery. However, the traditional approach to harvesting the ileocolon flap requires a midline laparotomy, which is associated with several donor site complications. In the literature, a minimally invasive approach for the harvest of this flap, which is complex, associated with numerous morbidities related to laparotomy, and has many modifications to perfect its outcomes, has not yet been defined. The purpose of this report is to describe the technique of robotic harvest of the free ileocolon flap to avoid the risks associated with laparotomy. A 53-year-old patient who underwent laryngectomy and cervical esophagectomy (15-cm defect) for treatment of laryngeal squamous cell carcinoma has been admitted to our department for restoration of voice and swallowing. The robotic surgery system (Da Vinci Xi, Intuitive Surgical) enables precise dissection of the ileum, colon, and ileocolic artery and vein by providing optimized high-definition visualization of the surgical field and enhanced control through robotic arms, which offer a much greater range of motion than the surgeon's hand or laparoscopic systems. The flap included 15 cm of ascending colon, ileocecal valve, 10 cm ileum (voice tube), and 5 cm of chimeric ileal segment (seromuscular patch flap). The flap insetted in the neck in an isoperistaltic fashion; ascending colon end-to-end to the esophageal stumps and voice tube anastomosed to tracheal stump in end-to-side fashion. The microvascular anastomoses were performed to the facial artery and external jugular vein. During a 4-month follow-up period, no complications were observed. The patient can eat solid food and speak with his own voice postoperatively. We believe that robotic harvesting of the free ileocolon flap is a safe, feasible, and effective technique that significantly reduces the risk of morbidity related to the invasiveness of the traditional flap harvesting technique.

MicrosurgeryVol. 45(4)
Hacettepe University (TR)
Openalex Percentile: Top 81%
Tracheal and airway disorders
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.