Hourly Daylight Illuminance Prediction Considering Seasonal and Daylight Condition-Based Meteorological Analog Intervals

With the growing global demand for energy optimization, particularly in the building sector, accurate daylight illuminance prediction plays a key role in enhancing energy efficiency through natural lighting and intelligent lighting systems. This study proposes a novel prediction model that integrates Meteorological Analog Intervals with a hybrid TCN-Transformer-BILSTM architecture to address the issue of insufficient prediction accuracy caused by the influence of various complex factors on daylight illuminance, as well as sudden weather changes, fluctuating meteorological conditions, and short-term variations. The model uses Grey Relational Analysis and Cosine Similarity to select historical data similar to the target moment in terms of meteorological conditions and time attributes, and constructs Meteorological Analog Intervals by combining the preceding and following time steps, providing high-quality data for the subsequent model development. The model effectively combines the multi-scale feature extraction capability of TCN, the global correlation-capturing advantage of Transformer, and the bidirectional temporal modeling characteristic of BILSTM to predict the temporal dynamics of daylight illuminance. Based on the measured data from Xi’an in 2023, experiments show that the proposed MAIL-TCN-Trans-BILSTM model achieves RMSEs of 1425.83 Lux and 2581.45 Lux under optimal and suboptimal daylight conditions, respectively, with MAPE reductions of 9–12% and 4–6% compared to baseline models. The proposed Meteorological Analog Intervals method significantly enhances the prediction accuracy and robustness of the model, especially in scenarios with complex and variable meteorological conditions, providing data support for intelligent lighting control systems.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-05-27
DOI
https://doi.org/10.3390/su17114914
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Hourly Daylight Illuminance Prediction Considering Seasonal and Daylight Condition-Based Meteorological Analog Intervals

Ying Yu, Jian Li Hao, Zhanliang Zhu, Xingyu Wang et al.
Sustainability
Building Energy and Comfort Optimization
article

Hourly Daylight Illuminance Prediction Considering Seasonal and Daylight Condition-Based Meteorological Analog Intervals

Ying Yu, Jian Li Hao, Zhanliang Zhu, Xingyu Wang, Linkun Yang
article en

Abstract

With the growing global demand for energy optimization, particularly in the building sector, accurate daylight illuminance prediction plays a key role in enhancing energy efficiency through natural lighting and intelligent lighting systems. This study proposes a novel prediction model that integrates Meteorological Analog Intervals with a hybrid TCN-Transformer-BILSTM architecture to address the issue of insufficient prediction accuracy caused by the influence of various complex factors on daylight illuminance, as well as sudden weather changes, fluctuating meteorological conditions, and short-term variations. The model uses Grey Relational Analysis and Cosine Similarity to select historical data similar to the target moment in terms of meteorological conditions and time attributes, and constructs Meteorological Analog Intervals by combining the preceding and following time steps, providing high-quality data for the subsequent model development. The model effectively combines the multi-scale feature extraction capability of TCN, the global correlation-capturing advantage of Transformer, and the bidirectional temporal modeling characteristic of BILSTM to predict the temporal dynamics of daylight illuminance. Based on the measured data from Xi’an in 2023, experiments show that the proposed MAIL-TCN-Trans-BILSTM model achieves RMSEs of 1425.83 Lux and 2581.45 Lux under optimal and suboptimal daylight conditions, respectively, with MAPE reductions of 9–12% and 4–6% compared to baseline models. The proposed Meteorological Analog Intervals method significantly enhances the prediction accuracy and robustness of the model, especially in scenarios with complex and variable meteorological conditions, providing data support for intelligent lighting control systems.

SustainabilityVol. 17(11)
Xi'an University of Architecture and Technology (CN)
Key Research and Development Projects of Shaanxi Province
Openalex Percentile: Top 88%
Building Energy and Comfort Optimization
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.