Short-Term Outcomes of First Metatarsophalangeal Arthroplasty Using the Silktoe Double-Stemmed Silicone Implant

<b>Background</b>: Hallux rigidus is a painful and degenerative pathology of the first metatarsophalangeal (MTP1) joint. In severe cases it is usually appropriate to consider arthrodesis or arthroplasty of the joint. Arthrodesis represents the gold standard, but arthroplasty allows patients to recover mobility. Although arthroplasty has slightly inferior functional results to arthrodesis, it has shown very good results in terms of joint mobility, patient satisfaction and pain reduction. The goal of the present study was to evaluate short-term outcomes of patients that received a third-generation double-stemmed MTP1 implant manufactured from high-performance silicon. <b>Methods</b>: In this retrospective study the authors analyzed data of 37 patients who underwent MPT1 joint arthroplasty with Silktoe<sup>TM</sup> double-stemmed implant using the R 4.2.2 software (R Foundation for Statistical Computing, Vienna, Austria). The indications were hallux rigidus of grade III and grade IV (81.1%), hallux rigidus plus valgus (10.8%), painful or unstable joint following previous surgery (5.4%) and hallux rigidus due to gout (2.7%). Data were collected during routine visits at 1 and 6 months and 1 and 2 years. <b>Results</b>: There were no intraoperative and postoperative complications. There were no revisions or reoperations at a follow-up of two years. The American Orthopaedic Foot and Ankle Society-Hallux Metatarsophalangeal-Interphalangeal Scale (AOFAS-HMI) score was 94.6 ± 7.6 (median, 100; range, 70-100) and the Visual Analogue Scale (VAS) score was 0.4 ± 0.80 (median, 0; range, 0-3.5) at the final follow-up. <b>Conclusions</b>: The data from this study presented excellent short-term results for patients who received an arthroplasty of the MTP1 joint using a third-generation double-stemmed spacer made of high-performance silicone. For all patients who received the Silktoe<sup>TM</sup> implant, AOFAS-HMI scores of 94.6 and VAS scores of 0.4 were obtained at a two-year follow-up. These values were in line with results reported in the literature for similar devices.

Authors

Publication Details

Journal
Diagnostics
Published
2025-05-27
DOI
https://doi.org/10.3390/diagnostics15111349
Primary Topic
Foot and Ankle Surgery
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Short-Term Outcomes of First Metatarsophalangeal Arthroplasty Using the Silktoe Double-Stemmed Silicone Implant

Stefano Fieschi, C. Redaelli, Anita Fazzini
Diagnostics
Foot and Ankle Surgery
article

Short-Term Outcomes of First Metatarsophalangeal Arthroplasty Using the Silktoe Double-Stemmed Silicone Implant

Stefano Fieschi, C. Redaelli, Anita Fazzini
article en

Abstract

<b>Background</b>: Hallux rigidus is a painful and degenerative pathology of the first metatarsophalangeal (MTP1) joint. In severe cases it is usually appropriate to consider arthrodesis or arthroplasty of the joint. Arthrodesis represents the gold standard, but arthroplasty allows patients to recover mobility. Although arthroplasty has slightly inferior functional results to arthrodesis, it has shown very good results in terms of joint mobility, patient satisfaction and pain reduction. The goal of the present study was to evaluate short-term outcomes of patients that received a third-generation double-stemmed MTP1 implant manufactured from high-performance silicon. <b>Methods</b>: In this retrospective study the authors analyzed data of 37 patients who underwent MPT1 joint arthroplasty with Silktoe<sup>TM</sup> double-stemmed implant using the R 4.2.2 software (R Foundation for Statistical Computing, Vienna, Austria). The indications were hallux rigidus of grade III and grade IV (81.1%), hallux rigidus plus valgus (10.8%), painful or unstable joint following previous surgery (5.4%) and hallux rigidus due to gout (2.7%). Data were collected during routine visits at 1 and 6 months and 1 and 2 years. <b>Results</b>: There were no intraoperative and postoperative complications. There were no revisions or reoperations at a follow-up of two years. The American Orthopaedic Foot and Ankle Society-Hallux Metatarsophalangeal-Interphalangeal Scale (AOFAS-HMI) score was 94.6 ± 7.6 (median, 100; range, 70-100) and the Visual Analogue Scale (VAS) score was 0.4 ± 0.80 (median, 0; range, 0-3.5) at the final follow-up. <b>Conclusions</b>: The data from this study presented excellent short-term results for patients who received an arthroplasty of the MTP1 joint using a third-generation double-stemmed spacer made of high-performance silicone. For all patients who received the Silktoe<sup>TM</sup> implant, AOFAS-HMI scores of 94.6 and VAS scores of 0.4 were obtained at a two-year follow-up. These values were in line with results reported in the literature for similar devices.

DiagnosticsVol. 15(11)
Openalex Percentile: Top 85%
Foot and Ankle Surgery
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.