Determining Indoor Parameters for Thermal Comfort and Energy Saving in Shopping Malls in Summer: A Field Study in China

Local data about indoor thermal comfort are in short supply, which are always different from the predicted results produced by models shown in previous studies. Shopping malls that consume substantial energy need to save energy, provided that thermal comfort is maintained. Therefore, this research investigated indoor thermal comfort using field measurements and questionnaires in a typical shopping mall in Danyang, China, with a hot summer and cold winter climate in order to explore local demands and energy-saving potential. The findings are as follows: (1) The average air temperature (Ta) and operative temperature (Top) are 26.7 °C and 26.4 °C, which implies a minor influence from radiation and other factors on Ta. Women are more sensitive to changes in outdoor temperature since clothing insulation (Icl) varies by gender: 0.31 clo and 0.36 clo for male and female individuals, respectively. (2) The thermal neutral temperature (TNT) derived from the thermal sensation vote (TSV) is 25.26 °C, which is significantly higher than the 21.77 °C obtained from the predicted mean vote (PMV) model. (3) There is a wide range of acceptable temperatures for thermal comfort because the highest temperature was identified by the thermal comfort vote (TCV) at 27.55 °C, followed closely by 27.48 °C, 26.78 °C, and 25.32 °C, which were separately derived from the thermal acceptance vote (TAV), TSV, and predicted percentage of dissatisfied (PPD) people; these were based on an upper limit of the acceptable 80% range. (4) In total, 94.85% of respondents accepted the indoor air quality, although the median concentration of CO2 was 772 ppm, and the neutral relative humidity level was 70.60%. Meanwhile, there is an important relationship between air quality satisfaction and operative temperature; thus, the temperature (26.93 °C) with peak satisfaction can enhance air quality perception and thermal comfort. (5) The energy savings that can be achieved are 25.77% and 9.12% at most based on acceptable thermal comfort compared with baseline energy consumption at 23 °C and 26 °C, respectively.

Authors

Institutions

Publication Details

Journal
Sustainability
Published
2025-05-26
DOI
https://doi.org/10.3390/su17114876
Citations
2
Primary Topic
Building Energy and Comfort Optimization
Type
article
Field-Weighted Citation Impact
2.01
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Determining Indoor Parameters for Thermal Comfort and Energy Saving in Shopping Malls in Summer: A Field Study in China

Yufei Zhao, Wenjing Xu, C.Y. Hua, Qiong He
2 citations
Sustainability
Building Energy and Comfort Optimization
2.01
article

Determining Indoor Parameters for Thermal Comfort and Energy Saving in Shopping Malls in Summer: A Field Study in China

Yufei Zhao, Wenjing Xu, C.Y. Hua, Qiong He
article en
2 citations

Abstract

Local data about indoor thermal comfort are in short supply, which are always different from the predicted results produced by models shown in previous studies. Shopping malls that consume substantial energy need to save energy, provided that thermal comfort is maintained. Therefore, this research investigated indoor thermal comfort using field measurements and questionnaires in a typical shopping mall in Danyang, China, with a hot summer and cold winter climate in order to explore local demands and energy-saving potential. The findings are as follows: (1) The average air temperature (Ta) and operative temperature (Top) are 26.7 °C and 26.4 °C, which implies a minor influence from radiation and other factors on Ta. Women are more sensitive to changes in outdoor temperature since clothing insulation (Icl) varies by gender: 0.31 clo and 0.36 clo for male and female individuals, respectively. (2) The thermal neutral temperature (TNT) derived from the thermal sensation vote (TSV) is 25.26 °C, which is significantly higher than the 21.77 °C obtained from the predicted mean vote (PMV) model. (3) There is a wide range of acceptable temperatures for thermal comfort because the highest temperature was identified by the thermal comfort vote (TCV) at 27.55 °C, followed closely by 27.48 °C, 26.78 °C, and 25.32 °C, which were separately derived from the thermal acceptance vote (TAV), TSV, and predicted percentage of dissatisfied (PPD) people; these were based on an upper limit of the acceptable 80% range. (4) In total, 94.85% of respondents accepted the indoor air quality, although the median concentration of CO2 was 772 ppm, and the neutral relative humidity level was 70.60%. Meanwhile, there is an important relationship between air quality satisfaction and operative temperature; thus, the temperature (26.93 °C) with peak satisfaction can enhance air quality perception and thermal comfort. (5) The energy savings that can be achieved are 25.77% and 9.12% at most based on acceptable thermal comfort compared with baseline energy consumption at 23 °C and 26 °C, respectively.

SustainabilityVol. 17(11)
Nanjing Tech University (CN)
Openalex Percentile: Top 14%
Building Energy and Comfort Optimization
2.01
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.