Zero-Sequence Flux Analysis Aiming for Reliable Detection of Broken Rotor Bars in Induction Motors
Rotor electrical faults may appear in induction motors. Typically, this fault evolves at a slow rate, thus making it prominent for early detection. However, it has been shown that multiple breakages at non-adjacent positions may not create signatures when the MCSA is applied. Although the analysis of the stator current during the start-up transient can reveal this fault reliably, there are several industrial applications where the motors do not experience frequent start-ups making such methods obsolete. This paper addresses this need, that of detecting the fault reliably at steady state. The authors have utilised the zero-sequence stray flux and show that this methodology can identify the fault independently from the stator winding connection to the supply or the size and geometry of the motor.
Authors
- Konstantinos N. Gyftakis (ORCID: https://orcid.org/0000-0002-9730-4267)
- Panagiotis A. Panagiotou (ORCID: https://orcid.org/0000-0001-5889-4412)
- Nikolaos Trachalakis
- Zihao Song (ORCID: https://orcid.org/0009-0007-4090-7976)
- Marios Salinas (ORCID: https://orcid.org/0009-0002-2131-6699)
Institutions
- Technical University of Crete (GR)
- University of Sheffield (GB)
Publication Details
- Journal
- IEEE Transactions on Industry Applications
- Published
- 2025-05-27
- DOI
- https://doi.org/10.1109/tia.2025.3574044
- Citations
- 2
- Primary Topic
- Non-Destructive Testing Techniques
- Type
- article
- Field-Weighted Citation Impact
- 1.43