Deformation simulation of lightning protection insulator structure under unbalanced insulation configuration

In order to analyze the stress performance of lightning protection insulator structures, this paper studied the stress deformation simulation of lightning protection insulators under unbalanced insulation configuration. The lightning protection insulator structures (samples 2 and 3) were compared with ordinary insulator structures (samples 1 and 4) through tensile load, wind deflection, and flutter tests. The results showed that samples 2 and 3 were undamaged under a tensile load of 100kN, which was superior to the ordinary sample; In the wind deflection and flutter tests, the stress distribution and deformation of lightning protection insulator sample 2 were significantly affected by wind direction and flutter amplitude, indicating that these factors are key to evaluating the structural performance of lightning protection insulators.

Authors

Institutions

Publication Details

Published
2025-05-27
DOI
https://doi.org/10.1117/12.3065971
Primary Topic
High voltage insulation and dielectric phenomena
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Deformation simulation of lightning protection insulator structure under unbalanced insulation configuration

Qiang Huang, Lou Ying
High voltage insulation and dielectric phenomena
article

Deformation simulation of lightning protection insulator structure under unbalanced insulation configuration

Qiang Huang, Lou Ying
article en

Abstract

In order to analyze the stress performance of lightning protection insulator structures, this paper studied the stress deformation simulation of lightning protection insulators under unbalanced insulation configuration. The lightning protection insulator structures (samples 2 and 3) were compared with ordinary insulator structures (samples 1 and 4) through tensile load, wind deflection, and flutter tests. The results showed that samples 2 and 3 were undamaged under a tensile load of 100kN, which was superior to the ordinary sample; In the wind deflection and flutter tests, the stress distribution and deformation of lightning protection insulator sample 2 were significantly affected by wind direction and flutter amplitude, indicating that these factors are key to evaluating the structural performance of lightning protection insulators.

Lishui City People's Hospital (CN)
Openalex Percentile: Top 92%
High voltage insulation and dielectric phenomena
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.

Deformation simulation of lightning protection insulator structure under unbalanced insulation configuration — Qiang Huang, Lou Ying · (2025) | TGRS Research Map | TGRS