An innovative and cost-effective method for hydrogen production from wastewater using a membraneless bioelectrolysis system

This study presents the development of a novel membraneless microbial electrolysis cell system for biohydrogen production using domestic anaerobic wastewater and sludge as the substrate and inoculum. The experimental design analyzed the effects of sludge/wastewater ratios ranging from 0.2 to 1.0, applied voltages between 1.0 V and 2.0 V, temperatures from 20°C to 60°C, and pH levels of 4, 7, and 10. Optimal conditions for biohydrogen production were identified as a sludge to wastewater ratio of 1.0, a voltage of 2.0 V, a temperature of 40°C, and a neutral pH, resulting in a peak biohydrogen yield of 862.792 mg/L. At the lowest sludge/wastewater ratio of 0.2, hydrogen production remained below 200 mg/L. Production increased to the range of 500 to 600 mg/L at a ratio of 0.6 and reached 800 mg/L at a ratio of 1.0. The impact of temperature was evident, with biohydrogen output rising from 300 mg/L at 20°C to 600 mg/L at 40°C, then stabilizing at higher temperatures. The applied voltage substantially affected hydrogen production, with yields below 400 mg/L at 1.0 V, increasing to 600 mg/L at 1.6 V, and reaching a maximum at 2.0 V. The highest biohydrogen production was achieved at neutral pH, while acidic and alkaline conditions reduced yields to below 200 mg/L. These findings underscore the importance of optimizing operational parameters to maximize biohydrogen production while effectively treating wastewater. The study also highlights the potential of integrating sustainable waste to energy technologies in wastewater management, advancing renewable energy production through process optimization. • Optimized membraneless MECs show promise for bioH2 production and wastewater treatment. • System optimized for bioH 2 using domestic wastewater and anaerobic sludge. • BioH 2 production reached a maximum at 2.0 V, while extreme pH conditions significantly reduced the yield. • Low sludge ratios resulted in bioH 2 production below 200 mg/L, while increasing ratios enhanced production above 800 mg/L. • BioH 2 production increased from 300 mg/L at 20 °C to 600 mg/L at 40 °C, stabilizing at higher temperatures.

Authors

Institutions

Publication Details

Journal
Journal of Water Process Engineering
Published
2025-05-27
DOI
https://doi.org/10.1016/j.jwpe.2025.107999
Citations
1
Primary Topic
Microbial Fuel Cells and Bioremediation
Type
article
Field-Weighted Citation Impact
0.80
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

An innovative and cost-effective method for hydrogen production from wastewater using a membraneless bioelectrolysis system

İbrahim Dinçer, Ahmet Faruk Kilicaslan
1 citations
Journal of Water Process Engineering
Microbial Fuel Cells and Bioremediation
0.80
article

An innovative and cost-effective method for hydrogen production from wastewater using a membraneless bioelectrolysis system

İbrahim Dinçer, Ahmet Faruk Kilicaslan
article en
1 citations

Abstract

This study presents the development of a novel membraneless microbial electrolysis cell system for biohydrogen production using domestic anaerobic wastewater and sludge as the substrate and inoculum. The experimental design analyzed the effects of sludge/wastewater ratios ranging from 0.2 to 1.0, applied voltages between 1.0 V and 2.0 V, temperatures from 20°C to 60°C, and pH levels of 4, 7, and 10. Optimal conditions for biohydrogen production were identified as a sludge to wastewater ratio of 1.0, a voltage of 2.0 V, a temperature of 40°C, and a neutral pH, resulting in a peak biohydrogen yield of 862.792 mg/L. At the lowest sludge/wastewater ratio of 0.2, hydrogen production remained below 200 mg/L. Production increased to the range of 500 to 600 mg/L at a ratio of 0.6 and reached 800 mg/L at a ratio of 1.0. The impact of temperature was evident, with biohydrogen output rising from 300 mg/L at 20°C to 600 mg/L at 40°C, then stabilizing at higher temperatures. The applied voltage substantially affected hydrogen production, with yields below 400 mg/L at 1.0 V, increasing to 600 mg/L at 1.6 V, and reaching a maximum at 2.0 V. The highest biohydrogen production was achieved at neutral pH, while acidic and alkaline conditions reduced yields to below 200 mg/L. These findings underscore the importance of optimizing operational parameters to maximize biohydrogen production while effectively treating wastewater. The study also highlights the potential of integrating sustainable waste to energy technologies in wastewater management, advancing renewable energy production through process optimization. • Optimized membraneless MECs show promise for bioH2 production and wastewater treatment. • System optimized for bioH 2 using domestic wastewater and anaerobic sludge. • BioH 2 production reached a maximum at 2.0 V, while extreme pH conditions significantly reduced the yield. • Low sludge ratios resulted in bioH 2 production below 200 mg/L, while increasing ratios enhanced production above 800 mg/L. • BioH 2 production increased from 300 mg/L at 20 °C to 600 mg/L at 40 °C, stabilizing at higher temperatures.

Journal of Water Process EngineeringVol. 75
Ontario Tech University (CA)
Clean water and sanitation
Openalex Percentile: Top 29%
Microbial Fuel Cells and Bioremediation
0.80
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.