A three-dimensional microfluidic device embedded within a thermal cycler tube for electrokinetic DNA extraction

Microfluidic devices have been widely used in modern chemical and biological analyses as stand-alone units, typically in series with other equipment such as extraction columns, manual or robotic pipetting, and even advanced next-generation sequencing systems. While microfluidic devices have enhanced various aspects of laboratory workflows, their integration with established commercial assay platforms remains limited. To this end, we developed a three-dimensional microfluidic insert embedded directly into a commercially available polymerase chain reaction (PCR) tube. This integration creates a microfluidic device compatible with conventional thermal cyclers, which support complex temperature cycling and multiplexed fluorescence detection. The integrated system facilitates key bioassay functions like nucleic acid purification through a selective ionic focusing method known as isotachophoresis (ITP), PCR amplification, and real-time fluorescence detection. We validated the performance of the integrated system by purifying nucleic acids from raw human serum samples and detecting exogenous SARS-CoV-2 N gene using FAM-labeled TaqMan probes, with both the DNA extraction and detection carried out within the same PCR tube. We achieved a detection sensitivity of 100 cp μL<sup>-1</sup> within a total process time of 60 min in these experiments. Human serum samples processed without purification show no PCR amplification results. This integrated system demonstrates the powerful concept of integrating microfluidic structures into form factors compatible with the highly complex and sensitive operation of current off-the-shelf systems.

Authors

Institutions

Publication Details

Journal
Lab on a Chip
Published
2025-01-01
DOI
https://doi.org/10.1039/d4lc01062k
Primary Topic
Microfluidic and Bio-sensing Technologies
Type
article
Field-Weighted Citation Impact
0.00

Funders

Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A three-dimensional microfluidic device embedded within a thermal cycler tube for electrokinetic DNA extraction

Xuehao Zang, Diego A. Huyke, Juan Gabriel Santiago, Alexandre Sivassangarin Avaro et al.
Lab on a Chip
Microfluidic and Bio-sensing Technologies
article

A three-dimensional microfluidic device embedded within a thermal cycler tube for electrokinetic DNA extraction

Xuehao Zang, Diego A. Huyke, Juan Gabriel Santiago, Alexandre Sivassangarin Avaro, Yilu Wang, Qi Jiang
article en

Abstract

Microfluidic devices have been widely used in modern chemical and biological analyses as stand-alone units, typically in series with other equipment such as extraction columns, manual or robotic pipetting, and even advanced next-generation sequencing systems. While microfluidic devices have enhanced various aspects of laboratory workflows, their integration with established commercial assay platforms remains limited. To this end, we developed a three-dimensional microfluidic insert embedded directly into a commercially available polymerase chain reaction (PCR) tube. This integration creates a microfluidic device compatible with conventional thermal cyclers, which support complex temperature cycling and multiplexed fluorescence detection. The integrated system facilitates key bioassay functions like nucleic acid purification through a selective ionic focusing method known as isotachophoresis (ITP), PCR amplification, and real-time fluorescence detection. We validated the performance of the integrated system by purifying nucleic acids from raw human serum samples and detecting exogenous SARS-CoV-2 N gene using FAM-labeled TaqMan probes, with both the DNA extraction and detection carried out within the same PCR tube. We achieved a detection sensitivity of 100 cp μL<sup>-1</sup> within a total process time of 60 min in these experiments. Human serum samples processed without purification show no PCR amplification results. This integrated system demonstrates the powerful concept of integrating microfluidic structures into form factors compatible with the highly complex and sensitive operation of current off-the-shelf systems.

Lab on a ChipVol. 25(16)
Centre National de la Recherche Scientifique (FR), Cornell University (US), Université Paris Sciences et Lettres (FR), Stanford University (US), ESPCI Paris (FR), Tsinghua University (CN)
Stanford University
Openalex Percentile: Top 89%
Microfluidic and Bio-sensing Technologies
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.