The optimal ionic concentration of sensing buffer in the detection of RNA by using the DNA probe with the silicon nanowire field-effect transistor (SiNW-FET)

This study investigates optimal conditions for surface modification and ionic concentration of sensing buffers for miRNA-21 detection using DNA probes on silicon nanowire field-effect transistor (SiNW-FET) biosensors. Ionic strength is a key factor influencing DNA/RNA hybridization efficiency and FET detection sensitivity by affecting duplex formation and the Debye length. An optimal balance between these effects is crucial for ultra-sensitive miRNA detection. The surface functionalization process was optimized through systematic testing of reaction time, temperature, and pH. A 30-min silanization reaction at room temperature without pH adjustment, followed by acetic acid rinsing, resulted in the most uniform silica surface. For hybridization detection, fluorescence microscopy showed that the highest ionic strength (150 mM) of Bis-Tris propane (BTP) buffer produced the greatest hybridization amount. Grazing-incidence small-angle X-ray scattering (GISAXS) confirmed stable secondary structures in DNA/DNA and DNA/RNA hybrids across all ionic strengths. For SiNW-FET measurements, BTP buffers with varying ionic strengths (10 mM, 50 mM, and 150 mM) were tested. A 50 mM BTP buffer provided the optimal balance between ionic strength for hybridization and electric double-layer structure, yielding the highest voltage shifts and enhanced sensitivity for ultra-low miRNA concentrations. Moreover, 50 mM BTP outperformed 50 mM PBS due to BTP's larger counterions reduced ion accumulation on the sensor surface, further improving sensitivity. These findings are crucial for advancing non-invasive liquid biopsy techniques in detecting low-concentration miRNAs.

Authors

Institutions

Publication Details

Journal
Talanta
Published
2025-05-27
DOI
https://doi.org/10.1016/j.talanta.2025.128375
Citations
5
Primary Topic
Advanced biosensing and bioanalysis techniques
Type
article
Field-Weighted Citation Impact
4.03
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

The optimal ionic concentration of sensing buffer in the detection of RNA by using the DNA probe with the silicon nanowire field-effect transistor (SiNW-FET)

Wen-Pin Hu, Bharath Kumar Yadlapalli, Wen‐Yih Chen, Jui-Shen Wang et al.
5 citations
Talanta
Advanced biosensing and bioanalysis techniques
4.03
article

The optimal ionic concentration of sensing buffer in the detection of RNA by using the DNA probe with the silicon nanowire field-effect transistor (SiNW-FET)

Wen-Pin Hu, Bharath Kumar Yadlapalli, Wen‐Yih Chen, Jui-Shen Wang, Y. C. Chiu, Tsung-Yi Huang
article en
5 citations

Abstract

This study investigates optimal conditions for surface modification and ionic concentration of sensing buffers for miRNA-21 detection using DNA probes on silicon nanowire field-effect transistor (SiNW-FET) biosensors. Ionic strength is a key factor influencing DNA/RNA hybridization efficiency and FET detection sensitivity by affecting duplex formation and the Debye length. An optimal balance between these effects is crucial for ultra-sensitive miRNA detection. The surface functionalization process was optimized through systematic testing of reaction time, temperature, and pH. A 30-min silanization reaction at room temperature without pH adjustment, followed by acetic acid rinsing, resulted in the most uniform silica surface. For hybridization detection, fluorescence microscopy showed that the highest ionic strength (150 mM) of Bis-Tris propane (BTP) buffer produced the greatest hybridization amount. Grazing-incidence small-angle X-ray scattering (GISAXS) confirmed stable secondary structures in DNA/DNA and DNA/RNA hybrids across all ionic strengths. For SiNW-FET measurements, BTP buffers with varying ionic strengths (10 mM, 50 mM, and 150 mM) were tested. A 50 mM BTP buffer provided the optimal balance between ionic strength for hybridization and electric double-layer structure, yielding the highest voltage shifts and enhanced sensitivity for ultra-low miRNA concentrations. Moreover, 50 mM BTP outperformed 50 mM PBS due to BTP's larger counterions reduced ion accumulation on the sensor surface, further improving sensitivity. These findings are crucial for advancing non-invasive liquid biopsy techniques in detecting low-concentration miRNAs.

TalantaVol. 295
Asia University (TW), National Central University (TW)
Openalex Percentile: Top 6%
Advanced biosensing and bioanalysis techniques
4.03
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.