A Study on the Performance and Efficiency of VRF System Air-conditioner based on the Smart Receiver

In the case of the next-generation VRF system air conditioner, in order to obtain the best performance and efficiency according to site climatic factors, installation environmental conditions, and operating load, an optimal amount of R410A refrigerant according to cooling and heating operation can be continuously and intelligently varied by applying a Smart Receiver to an outdoor unit. By utilizing the amount of refrigerant charged in this receiver, sufficient target condensation pressure can be maintained to secure the outlet temperature of the indoor unit above 40 degrees Celsius during full load operation even if the outdoor temperature falls below -10 degrees Celsius during heating operation. On the other hand, during cooling operation, the refrigerant is appropriately stored in the receiver according to the indoor cooling load to prevent unnecessary increases in condensation pressure, secure the target evaporation pressure, and smartly control to reduce the amount of charged refrigerant. By improving performance according to operating conditions, a smart receiver that takes efficiency into consideration can be applied.

Authors

Publication Details

Journal
Korean Journal of Air-Conditioning and Refrigeration Engineering
Published
2025-05-27
DOI
https://doi.org/10.6110/kjacr.2025.37.5.207
Primary Topic
Internet of Things and Social Network Interactions
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

A Study on the Performance and Efficiency of VRF System Air-conditioner based on the Smart Receiver

Seung Jun Lee
Korean Journal of Air-Conditioning and Refrigeration Engineering
Internet of Things and Social Network Interactions
article

A Study on the Performance and Efficiency of VRF System Air-conditioner based on the Smart Receiver

Seung Jun Lee
article en

Abstract

In the case of the next-generation VRF system air conditioner, in order to obtain the best performance and efficiency according to site climatic factors, installation environmental conditions, and operating load, an optimal amount of R410A refrigerant according to cooling and heating operation can be continuously and intelligently varied by applying a Smart Receiver to an outdoor unit. By utilizing the amount of refrigerant charged in this receiver, sufficient target condensation pressure can be maintained to secure the outlet temperature of the indoor unit above 40 degrees Celsius during full load operation even if the outdoor temperature falls below -10 degrees Celsius during heating operation. On the other hand, during cooling operation, the refrigerant is appropriately stored in the receiver according to the indoor cooling load to prevent unnecessary increases in condensation pressure, secure the target evaporation pressure, and smartly control to reduce the amount of charged refrigerant. By improving performance according to operating conditions, a smart receiver that takes efficiency into consideration can be applied.

Korean Journal of Air-Conditioning and Refrigeration EngineeringVol. 37(5)
Affordable and clean energy
Openalex Percentile: Top 88%
Internet of Things and Social Network Interactions
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.