Ear Canal Role and Psychoacoustic Parameters: Loudness, Sharpness, Roughness, and Fluctuation Strength

Abstract Aim: The purpose of this study was to investigate whether psychoacoustic parameters could be significantly influenced by the human ear canal and whether gender played a significant role in these effects. Methods: In this study, sixty participants were enrolled, with an equal distribution of 30 male and 30 female individuals. White and sinusoidal noises at 75, 85, and 95 dB as stimulus sound pressure levels (SSPLs). Psychoacoustic parameters such as loudness, sharpness, roughness, and fluctuation strength were measured both outside (cavum part of the external ear) and inside the right ear of each participant. These measurements were done using a circular-shaped microphone with a 2-mm diameter and Labview software. The duration for each measurement was 10 s. The independent sample t -test and repeated measures ANOVA test were employed for the statistical analysis in this study. The results indicated that the equality of means was rejected at a significance level of P < 0.05. All statistical analyses were conducted using SPSS Version 26. Results: The mean age and standard deviation of all participants were 22.77 ± 2.60 years old. The comparison of psychoacoustic parameters in the exposure to different types of noises at various levels between genders showed no statistically significant differences (all P > 0.05). For both sinusoidal noise and white noise at all three studied SSPLs, the differences in four psychoacoustic parameters between the outer and inner ears of the participants were not statistically significant (all P > 0.05). Conclusion: Based on our findings, it seems that the human ear canal does not have any effect on psychoacoustic parameters, leading us to conclude that the ear canal does not contribute to noise-induced annoyance.

Authors

Institutions

Publication Details

Journal
International Journal of Environmental Health Engineering
Published
2025-05-01
DOI
https://doi.org/10.4103/ijehe.ijehe_11_24
Primary Topic
Noise Effects and Management
Type
article
Field-Weighted Citation Impact
0.00
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Ear Canal Role and Psychoacoustic Parameters: Loudness, Sharpness, Roughness, and Fluctuation Strength

Siamak Pourabdian, Hadi Asady, Farhad Forouharmajd, Adrián Fuente et al.
International Journal of Environmental Health Engineering
Noise Effects and Management
article

Ear Canal Role and Psychoacoustic Parameters: Loudness, Sharpness, Roughness, and Fluctuation Strength

Siamak Pourabdian, Hadi Asady, Farhad Forouharmajd, Adrián Fuente, Fatemeh Ansari, Mehdi Jalali, Ali Reza Ahmadi
article en

Abstract

Abstract Aim: The purpose of this study was to investigate whether psychoacoustic parameters could be significantly influenced by the human ear canal and whether gender played a significant role in these effects. Methods: In this study, sixty participants were enrolled, with an equal distribution of 30 male and 30 female individuals. White and sinusoidal noises at 75, 85, and 95 dB as stimulus sound pressure levels (SSPLs). Psychoacoustic parameters such as loudness, sharpness, roughness, and fluctuation strength were measured both outside (cavum part of the external ear) and inside the right ear of each participant. These measurements were done using a circular-shaped microphone with a 2-mm diameter and Labview software. The duration for each measurement was 10 s. The independent sample t -test and repeated measures ANOVA test were employed for the statistical analysis in this study. The results indicated that the equality of means was rejected at a significance level of P < 0.05. All statistical analyses were conducted using SPSS Version 26. Results: The mean age and standard deviation of all participants were 22.77 ± 2.60 years old. The comparison of psychoacoustic parameters in the exposure to different types of noises at various levels between genders showed no statistically significant differences (all P > 0.05). For both sinusoidal noise and white noise at all three studied SSPLs, the differences in four psychoacoustic parameters between the outer and inner ears of the participants were not statistically significant (all P > 0.05). Conclusion: Based on our findings, it seems that the human ear canal does not have any effect on psychoacoustic parameters, leading us to conclude that the ear canal does not contribute to noise-induced annoyance.

International Journal of Environmental Health EngineeringVol. 14(2)
Isfahan University of Medical Sciences (IR), University of Neyshabur (IR), Institut Universitaire de Gériatrie de Montréal (CA)
Openalex Percentile: Top 84%
Noise Effects and Management
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.