Fabrication of Antibiofilm-Based-Polymer Nanocomposite for Biophysical Applications

Polymer nanocomposites attracted significant interest because of their effective characterization and low cost. This investigation aims to fabricate newly cost-effective blended polymer polyethylene oxide (PEO), carboxymethyl cellulose (CMC), and conductive nano-polyaniline (PANI) were improved by different loading ratios of hybrid graphene oxide (Fixed ratio = 0.05 %) and different loading ratio of silicon nitride (0.05, 0.25, and 0.45 %), (GO-Si3N4) nanomaterials to fabricated nanocomposites. PEO-CMC-PANI/GO-Si3N4 composites were fabricated using the acoustic-ultrasonic method. The semicrystalline performance of samples was proved using X-ray diffraction, and Fourier-transform infrared spectroscopy exposed strong interfacial interaction. Field emission scanning electron microscopies showed homogenous samples with fine nanomaterial dispersion in the matrix, revealing significant changes. The transparency of the samples was increased with the rise in the nanomaterial’s ratio, with the main electron transitions at about 280 nm wavelengths due to reducing the optical band gap from 3.5 to 2.6 and 2.8 eV of allowed and forbidden transitions. The inhibition of biofilm formation by the nanocomposite at a concentration of 5 % for bacterial isolates of Escherichia coli and Streptococcus mutans was increased compared to untreated bacteria. The optical density of S. mutants and E. coli was improved from 0.95, 0.2, and 0.4 mm, respectively. These nanocomposites presented good and cheap materials with a high aptitude for killing bacteria. They could be used in various biological and related applications, such as coating operating rooms, tools, cleaning, and even replacing traditional disinfectants. HIGHLIGHTS Impact of Si3N4-GO ratio nanomaterials reinforced newly blended polymers-based nanocomposites. Reducing the optical band gap from 3.5 to 2.6 and 2.8 eV of allowed and forbidden transitions. The optical density of mutants and E. coli was improved from 0.95, 0.2, and 0.4 mm. GRAPHICAL ABSTRACT

Authors

Institutions

Publication Details

Journal
Trends in Sciences
Published
2025-05-01
DOI
https://doi.org/10.48048/tis.2025.9762
Citations
1
Primary Topic
Bone Tissue Engineering Materials
Type
article
Field-Weighted Citation Impact
0.67
Controls
|||
ALL TIME
JAN
FEB
MAR
APR
MAY
JUN
JUL
AUG
SEP
OCT
article

Fabrication of Antibiofilm-Based-Polymer Nanocomposite for Biophysical Applications

Ehssan Al‐Bermany, Rawaa A. Abdul-Nabi
1 citations
Trends in Sciences
Bone Tissue Engineering Materials
0.67
article

Fabrication of Antibiofilm-Based-Polymer Nanocomposite for Biophysical Applications

Ehssan Al‐Bermany, Rawaa A. Abdul-Nabi
article en
1 citations

Abstract

Polymer nanocomposites attracted significant interest because of their effective characterization and low cost. This investigation aims to fabricate newly cost-effective blended polymer polyethylene oxide (PEO), carboxymethyl cellulose (CMC), and conductive nano-polyaniline (PANI) were improved by different loading ratios of hybrid graphene oxide (Fixed ratio = 0.05 %) and different loading ratio of silicon nitride (0.05, 0.25, and 0.45 %), (GO-Si3N4) nanomaterials to fabricated nanocomposites. PEO-CMC-PANI/GO-Si3N4 composites were fabricated using the acoustic-ultrasonic method. The semicrystalline performance of samples was proved using X-ray diffraction, and Fourier-transform infrared spectroscopy exposed strong interfacial interaction. Field emission scanning electron microscopies showed homogenous samples with fine nanomaterial dispersion in the matrix, revealing significant changes. The transparency of the samples was increased with the rise in the nanomaterial’s ratio, with the main electron transitions at about 280 nm wavelengths due to reducing the optical band gap from 3.5 to 2.6 and 2.8 eV of allowed and forbidden transitions. The inhibition of biofilm formation by the nanocomposite at a concentration of 5 % for bacterial isolates of Escherichia coli and Streptococcus mutans was increased compared to untreated bacteria. The optical density of S. mutants and E. coli was improved from 0.95, 0.2, and 0.4 mm, respectively. These nanocomposites presented good and cheap materials with a high aptitude for killing bacteria. They could be used in various biological and related applications, such as coating operating rooms, tools, cleaning, and even replacing traditional disinfectants. HIGHLIGHTS Impact of Si3N4-GO ratio nanomaterials reinforced newly blended polymers-based nanocomposites. Reducing the optical band gap from 3.5 to 2.6 and 2.8 eV of allowed and forbidden transitions. The optical density of mutants and E. coli was improved from 0.95, 0.2, and 0.4 mm. GRAPHICAL ABSTRACT

Trends in SciencesVol. 22(6)
University of Babylon (IQ), Al-Furat Al-Awsat Technical University (IQ)
Openalex Percentile: Top 31%
Bone Tissue Engineering Materials
0.67
AI Navigator

Ask Laika to Summarize, Analyze, and Connect papers live on the map.

Summarize Papers & Methodologies

Extract key findings, datasets, and comparative methods across publications.

Benchmark Rankings & Visual Analytics

Rank top research institutions, authors, funders, topics, and journals by Field-Weighted Citation Impact (FWCI) and paper volume with instant charts.

Connect Distant Disciplines

Bridge topological clusters on the map to find hidden collaborative intersections.